Memory formatting
Format the memory to be used by the "PC Memory Formatting" of Programming
*3
tool.
Writing the parameters and programs
Write the parameters and programs created by the programming tool into the
CPU module.
System reboot
Turn off and on the system power supply, or reset the CPU module.
Error check
Confirm that the ERR.LED of the CPU module is off.
If the ERR.LED is on or flashing, identify the error cause by the system monitor
or diagnostics of the programming tool
If the error is related to the parameters or programs, correct them.
Running of the CPU module
Run the CPU module, and then confirm that the RUN LED of the CPU module
turns on.
*1
The following types of diagnostics are available.
• PLC diagnostics
• Ethernet diagnostics
• CC IE Control diagnostics
• CC IE Field diagnostics
• MELSECNET diagnostics
• CC-Link and CC-Link/LT diagnostics
*2
CPU modules with a large-capacity program memory may require time before they go into the RUN status.
*3
The Basic model QPCU of the function version B or later does not require formatting the standard RAM, but it requires
clearing the standard RAM. For clearing the standard RAM (file register), refer to the following.
Qn(H)/QnPH/QnPRHCPU User's Manual (Function Explanation, Program Fundamentals)
For details of the wiring, connection, and initial settings of intelligent function modules, special function modules, and
network modules, refer to manuals for intelligent function modules, special function modules, and network module used.
58
(From previous page)
*1
to eliminate the error cause.
*2
Completed
Operating manual for the
• • •
programming tool used
Operating manual for the
• • •
programming tool used
Page 119, CHAPTER 6
• • •
Page 276, CHAPTER 15
• • •
Page 119, CHAPTER 6
• • •

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents