Mitsubishi Electric Q26UD(E)HCPU User Manual page 585

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

Number
Name
Meaning
Other
Error
system error
information
SD1614
information
category
category
code
Other
SD1615
Error
system error
to
common
common
SD1625
information
information
Other
SD1626
Error
system error
to
individual
individual
SD1636
information
information
Standby
Error code of
system error
SD1649
the error to
cancel
be cleared
command
Other
Other
system
system
SD1650
operating
operating
information
information
Network
Network
module
module
head
head
address,
address,
which
which
SD1690
requested
requested
system
system
switching on
switching on
host
host
(control)
(control)
system
system
Explanation
• The error information category codes for individual
information and common information of the error occurred in
the other system are stored.
• Data format is the same as SD4.
• The value in SD4 of the CPU module on the other system is
reflected.
• Stores the common information corresponding to the error
code stored in this system CPU.
• Data composition is the same as SD5 to SD15.
• The values in SD5 to SD15 of the CPU module on the other
system are reflected.
• The individual information of the error occurred in the other
system is stored.
• Data composition is the same as SD16 to SD26.
• The values in SD16 to SD26 of the CPU module on the
other system are reflected.
• The code of the error to be cleared by the standby system
error cancel command is stored.
• The standby system error is cleared by turning SM1649
from off to on after storing the error code of the error to clear.
• The least significant digit (ones place) of the error code in
this register is ignored. (The errors corresponding to error
codes 4100 to 4109 are cleared by storing 4100 in this
register.)
The operating information of the CPU module on the other
system is stored in the following bit pattern.
When communications with other systems are disabled or the
system is in the debug mode, "00FF
H
b15
to
b8
b7
to
b4
b3 b0
to
0
SD1650
0:No error
1:Continue error
2:Stop error
F:Communication with
other system
1
disabled
0:RUN
2:STOP
3:PAUSE
F:Communication with
other system
1
disabled
Note:
Communications are disabled in the following states.
• The other system is powered off or is being reset.
• A hardware failure has occurred on the host or the other
system.
• A watchdog timer error has occurred on the host or the other
system.
• Tracking cable is not connected. Tracking cable is broken or
failed.
• When system switching is requested from a network module
in the other system, the bit corresponding to the module that
received the request turns on.
b11
b1 b0
b1 to b11: Slot No.1 to slot No.11 (Slot No.0 (b0) is invalid
because the CPU module occupies two slots.)
• The system turns off the bit after the error in the
corresponding module is removed by a user.
• To find the number for the module where system switching is
requested from a network module in the host system, refer
to SD1590.
Set by
(When Set)
S (Every
END
processing)
S (Every
END
processing)
S (Every
END
processing)
S (Every
END
processing)
" is stored.
S (Every
END
1 Communication
with other system
processing)
disabled, debug
mode
S (Every
END
processing)
APPENDICES
Corresponding
Corresponding
host CPU
CPU
*2
SD
SD4
QnPRH
SD5 to SD15
QnPRH
SD16 to SD26
QnPRH
QnPRH
QnPRH
QnPRH
583
A

Hide quick links:

Advertisement

Table of Contents
loading