CAUTION
Emergency stop might be triggered if
return-to-origin is simultaneously
performed on three or more axes
whose return-to-origin method is the
stroke end detection method. In this
case, change the setting so that stroke
end return-to-origin is simultaneously
performed on two axes or is
performed separately on each axis.
n
NOTE
• Basically, use the MPB (teaching
pendant) to perform absolute
reset.
• Absolute reset can also be
performed by dedicated input.
However, this technique is limited
to axes using the stroke end
method or sensor method for
detecting the origin. This
dedicated input technique will also
not work if origin incomplete
occurs on axes set by the mark
method.

11.8 Absolute reset

Absolute reset is an operation to find the origin position, when the position detector in the
motor cannot identify the origin position (called "origin incomplete" from now on).
Movement commands in robot language cannot be executed if the origin is incomplete.
Always perform absolute reset if the origin is incomplete.
Origin incomplete may occur due to the following conditions.
a. An absolute-related error occurred on the axis.
17.73:D?.Resolver wire breakage
17.91:D?.Cannot perform ABS.reset
b. Absolute battery wire breakage or voltage drop was detected by the controller.
c. Cable connecting to the robot unit from the robot Controller was disconnected. (This
is the status when shipped from the factory.)
d. Robot generation was changed.
e. Parameters were initialized.
f. Axis-related parameters such as "Origin shift", "Origin detection method" and "Origin
return direction" and "Axis polarity" were changed. (This occurs when some parameters
were changed.)
g. Motor was replaced.
h. All data files (data file with extension "ALL") or parameter files (data files with
extension "PRM") were written into the robot controller.
Origin incomplete errors are listed below. These errors occur during startup of the robot
controller.
17.81:D?.ABS.battery wire breakage
17.83:D?.Backup position data error 1
17.85:D?.Backup position data error 2
17.92:D?.Resolver disconnected during power off
17.93:D?.Position backup counter overflow
11. "MANUAL" mode
etc.