6.28 : PATH without END
Code
Meaning/Cause : PATH START was executed without executing PATH END.
Action
6.29 : No PATH data
Code
Meaning/Cause : No path is set for PATH motion.
Action
6.30 : Too many PATH data
Code
Meaning/Cause : The number of PATH motion paths has exceeded 300.
Action
6.31 : Not PATH start position
Code
Meaning/Cause : Robot's current position is not the start position of PATH motion.
Action
6.32 : PATH execute error
Code
Meaning/Cause : Cannot execute PATH motion.
Action
6.33 : ABS of MARK incomplete
Code
Meaning/Cause : Absolute reset was attempted with an ABSRST statement or
Action
: &H061C
: Execute PATH END to end the path setting and then execute
PATH START.
: &H061D
: Set a path with PATH L and PATH C. The previously set path
will be lost in the following cases:
• When PATH SET is executed.
• When program is changed.
• When program is reset.
• When controller power is turned off.
: &H061E
: Reduce the number of PATH motion paths to 300 or less in total
of straight lines and circular arcs.
: &H061F
: Move the robot to the start position specified with PATH SET
and then execute PATH START.
: &H0620
a. Acceleration zone distance is too short.
b. Speed is too high in the position where the direction changes.
: 1. Reduce the speed setting.
2. Lengthen the straight line or circular arc distance containing
acceleration/deceleration.
3. Make setting so that the direction at the connection point of
straight lines does not change greatly.
: &H0621
dedicated input while absolute reset on an axis whose return-to-
origin method is set to "Mark" is incomplete.
: First perform absolute reset on the axes whose return-to-origin
method is set to "Mark".