GS1 DataBar Omnidirectional
•
Prefix must be ASCII characters ']e0'
•
Check character must be included in label
•
Application identifier "01" must follow the prefix and precede the base
label
•
Label length excluding prefix characters must be 16 characters.
•
Example: ']e00101044123456789'
GS1 DataBar Expanded
•
Prefix must be ASCII characters ']e0'
•
Label length excluding prefix characters must be at least 1 character.
Maximum length is the maximum label size supported by the scanner.
•
The format of the label must not be of the same format as RSS-14 (appli-
cation id & length equal to 16)
•
Example: ']e002900123456789083103001750'
Interleaved 2 of 5 (I 2 of 5)
•
Check character must be included in label data
•
Label length including check characters and excluding prefix characters
must meet requirements imposed by the main scanner's fixed or variable
label length control for this symbology type.
•
Prefix must be an ASCII character ']I1' (other prefixes specify different
check character properties which are not supported).
•
Example: ']I10123456789'
Code 128 / EAN 128
•
Prefix must be either ASCII characters ']C0', ']C1' or ']C2'
•
Label length excluding prefix character must meet requirements imposed
by the main scanner's fixed or variable label length control for this sym-
bology type.
•
If CI_EAN128_ENABLED is TRUE and prefix is ']C1', label will be identified
as an EAN128 otherwise it is identified as a Code 128.
•
A prefix of ']C0' designates that no function code is present in the 1st or
2nd character position
•
A prefix of ']C2' designates that a function code 1 is present in the 2nd
character.
•
Example : ']C0Code_128.Test'
Standard 2 of 5 (S 2 of 5)
•
Prefix must be ASCII characters ']S0'
•
Label length excluding prefix characters must meet requirements imposed
by the main scanner's fixed or variable label length control for this sym-
bology type.
•
Example : ']S01234567890'
440