Datalogic MAGELLAN 9800i Product Reference Manual page 288

Hide thumbs Also See for MAGELLAN 9800i:
Table of Contents

Advertisement

Enter/Exit Programming Mode
P5 Addon Minimum Read
This feature specifies the minimum number of times a P5 addon must decode
before it is marked valid.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the barcode representing the desired option on this and the following
3. Complete the programming sequence by scanning the Enter/Exit Pro-
007D01(CR)
P5 Addon Minimum Read = 1
007D03(CR)
P5 Addon Minimum Read = 3
007D05(CR)
P5 Addon Minimum Read = 5
278
page. You'll need to cover any unused barcodes on facing pages to ensure
that the scanner reads only the barcode you intend to scan.
gramming Mode bar code.
Other UPC/EAN Options
DEFAULT
007D02(CR)
P5 Addon Minimum Read = 2
007D04(CR)
P5 Addon Minimum Read = 4
007D06(CR)
P5 Addon Minimum Read = 6
Magellan™ 9800i Scanner