Site Preparation and Installation
Scanner Weights
When selecting materials and designing supports for scanner installation, don't
forget to factor in the weight of the scanner or scanner-scale and the products
that will need to be weighed or scanned during checkout.
Model
9801
9803/9804
9805/9806
TDR adds 0.3 kg (0.75 lb).
Flange Mount vs. Shelf Mount
Flange mount scanners and scanner-scales are supported in the counter by
brackets built into the front and back of the scanner. The flange brackets rest in
a recessed pocket in the countertop and the scanner is suspended between
them.
Shelf mount scanners and scanner-scales are supported by means of a shelf
directly under the body of the scanner.
See the figure below for easy identification of flange and shelf mount scanners.
Figure 9. Flange Mount vs. Shelf Mount
22
Description
Short Shelf Mount Scanner
Medium Shelf Mount Scanner
Long Flange Mount Scanner
SHELF MOUNT
Scanner Weight
Scanner/Scale
(w/o scale)
Weight
6.7 kg (14.75 lb)
N/A
6.8 kg (15.0 lb)
8.6 kg (19.0 lb)
6.9 kg (15.25 lb)
8.7 kg (19.25 lb)
FLANGE MOUNT
Front and rear brackets
Magellan™ 9800i Scanner