Datalogic MAGELLAN 9800i Product Reference Manual page 38

Hide thumbs Also See for MAGELLAN 9800i:
Table of Contents

Advertisement

Site Preparation and Installation
Max. Radius = 0.64cm
29.53cm
NOTE
3. Drill any holes required to install the AC/DC Power Supply, the Remote
28
Counter Cutout Dimensions
(0.25") 4x
1.91cm
(0.75")
(11.63")
Flange Support
0.95cm
(0.38")
If leveling screws are needed for models 9805 and 9806,
place in the locations marked with plus signs (+).
1.91cm
(0.75")
Drainage
If you plan to use a router on a countertop with a thickness of 1.9
cm (0.75") plywood, you'll need to add a backing strip that supports
the area routed out for the support flanges (see Figure 10). This
support strip should minimally be made of 1.9 cm (0.75") thick ply-
wood and be approximately 10.2 cm (4.0") wide and 35.6 cm (14.0")
long. This strip should be glued as well as screwed to the underside
of the countertop.
Scale Display cable and the interface cable(s) observing the following:
• Interface cables (and display cable, if applicable) should be routed away
from all highly inductive electrical devices, like motors and conveyor
belts, and even away from the unit's power cable if possible. See also
"Recommended Power Installation" on page
• Cables should be easy to remove in the event that replacement is
required. A little planning now will save a lot of frustration later. See also
"Service Access Requirements" on page
LONG (FLANGE MOUNT)
Models 9805 and 9806
51.12cm
(20.13")
47.31cm
(18.63")
1.91cm
(0.75")
Liquid
19.
Flange Support
7.62cm
(3.0")
7.62cm
(3.0")
0.95cm
(0.38")
1.26cm
(0.5")
Liquid
Drainage
1.91cm
(0.75")
19.
Magellan™ 9800i Scanner

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents