Deactivation (Tri-color) LED is
Deactivate
flashing slowly Red. FRU Status
EAS System
LED displays error code nine (9)
When Failed
Deactivation (Tri-color) LED
Deactivation
flashes Red.
Indicated
Deactivation (Tri-color) LED
flashes Red, then Orange, then
Deactivation
returns to Green.
Indicated
a. Additionally, the FRU LED (Health & Status Indicator located in the bottom of the optic cavity — visible through
the horizontal scan window) blinks the number '9'. If EAS deactivation fails to initiate, a low, error tone will be
sounded, and the FRU LED will display the error code '9' steadily (without flashing).
b. Ticking sound will stop upon one of the following: 1) Manual EAS Deactivation Push Button is pressed and
released again, 2) EAS timer runs out, or 3) Following a successful EAS tag deactivation.

ScaleSentry / Scale Service Button

The ScaleSentry / Scale Service Button is used for multiple functions:
PRESS DURATION
Momentary
4 Seconds
8 Seconds
Momentary while in
Scale Diagnostics Mode
a. Diagnostics Mode is meant for use by trained systems support personnel. Users should not need to
initiate this function under normal circumstances.
NOTE
394
Upon initiating this state
(pressing EAS Button for
3 seconds): 3 high-
pitched beeps
DECOUPLED MODE
EAS Beep OFF
HYBRID MODE
High frequency beep
FUNCTION
COMMENT
If a ScaleSentry event is occurring, this will override the
Override
scale sentry event. If no ScaleSentry event is occurring,
this will activate the manual tare function of the scale.
Allows system support personnel to troubleshoot prob-
lems with the scale. Momentarily press the Scale Zero
Scale Diagnostics
Button or cycle power to exit. See the topic,
a
Mode
Reporting on page 67
on page 63
Resets Scanner
Only system support personnel should perform a reset.
A scanner reset can also be initiated by a momentary
Resets Scanner
press of this button while in Scale Diagnostics Mode.
This function may not apply to Adaptive Scale models.
Upon EAS malfunction/failure,
scanning function can continue
independent of EAS if the EAS
button is held for 3 seconds.
An EAS tag has been success-
fully deactivated.
An EAS tag has been success-
fully deactivated.
Problem Isolation
in the
section for more details.
Magellan™ 9800i Scanner
Scale Error

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents