Workflow

receives at least one time slot. To disable an HSU you must deregister it. (A suspend mech-
anism is also available, to suspend service on an HSU for a fixed period.)
For each registered HSU, you can set separately, the Uplink and Downlink Maximum Infor-
mation Rate (MIR) in Mbps or leave it at Best Effort.
You may also mange an HSU Connection table to enable and disable connectivity between
HSUs in a sector.
Workflow
In this chapter, we assume that you are familiar with the material of
centrate on setup workflow assuming that you are familiar with GUI.
Prior to commencing, you should have written sector plan along the lines of

Configuring the Sector out of the Box - IP Addresses

The default log-on IP address for all ODUs in the sector is the same: 10.0.0.120, Netmask
255.0.0.0 and default gateway 0.0.0.0. To get the process started, set up the IP address on
the network card on the managing computer to something like 10.0.0.100, Netmask
255.255.255.0 and default gateway 0.0.0.0.
Ensure that you have a direct LAN connection to the ODU, run the RADWIN Manager and log-
on to it.