Edge-Core ECS4810-12M Layer 2 Management Manual page 173

Hide thumbs Also See for ECS4810-12M Layer 2:
Table of Contents

Advertisement

CLI R
EFERENCES
"Interface Commands" on page 949
C
U
OMMAND
SAGE
Cable diagnostics are performed using Digital Signal Processing (DSP)
test methods. DSP analyses the cable by sending a pulsed signal into
the cable, and then examining the reflection of that pulse.
Cable diagnostics can only be performed on twisted-pair media.
This cable test is only accurate for cables 7 - 100 meters long.
The test takes approximately 5 seconds. The switch displays the results
of the test immediately upon completion, including common cable
failures, as well as the status and approximate length to a fault.
Potential conditions which may be listed by the diagnostics include:
OK: Correctly terminated pair
Open: Open pair, no link partner
Short: Shorted pair
Not Supported: This message is displayed for any Gigabit Ethernet
ports linked up at a speed lower than 1000 Mbps.
Impedance mismatch: Terminating impedance is not in the
reference range.
Ports are linked down while running cable diagnostics.
P
ARAMETERS
These parameters are displayed:
Port – Switch port identifier.
Type – Displays media type. (GE – Gigabit Ethernet, Other – SFP)
Link Status – Shows if the port link is up or down.
Test Result – The results include common cable failures, as well as the
status and approximate distance to a fault, or the approximate cable
length if no fault is found.
To ensure more accurate measurement of the length to a fault, first
disable power-saving mode on the link partner before running cable
diagnostics.
For link-down ports, the reported distance to a fault is accurate to
within +/- 2 meters. For link-up ports, the accuracy is +/- 10 meters.
Last Updated – Shows the last time this port was tested.
– 173 –
| Interface Configuration
C
5
HAPTER
Port Configuration

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs4810-12m

Table of Contents