CLI R
EFERENCES
◆
"Interface Commands" on page 949
C
U
OMMAND
SAGE
Cable diagnostics are performed using Digital Signal Processing (DSP)
◆
test methods. DSP analyses the cable by sending a pulsed signal into
the cable, and then examining the reflection of that pulse.
Cable diagnostics can only be performed on twisted-pair media.
◆
◆
This cable test is only accurate for cables 7 - 100 meters long.
The test takes approximately 5 seconds. The switch displays the results
◆
of the test immediately upon completion, including common cable
failures, as well as the status and approximate length to a fault.
Potential conditions which may be listed by the diagnostics include:
◆
OK: Correctly terminated pair
■
Open: Open pair, no link partner
■
Short: Shorted pair
■
Not Supported: This message is displayed for any Gigabit Ethernet
■
ports linked up at a speed lower than 1000 Mbps.
Impedance mismatch: Terminating impedance is not in the
■
reference range.
Ports are linked down while running cable diagnostics.
◆
P
ARAMETERS
These parameters are displayed:
◆
Port – Switch port identifier.
Type – Displays media type. (GE – Gigabit Ethernet, Other – SFP)
◆
Link Status – Shows if the port link is up or down.
◆
Test Result – The results include common cable failures, as well as the
◆
status and approximate distance to a fault, or the approximate cable
length if no fault is found.
To ensure more accurate measurement of the length to a fault, first
disable power-saving mode on the link partner before running cable
diagnostics.
For link-down ports, the reported distance to a fault is accurate to
within +/- 2 meters. For link-up ports, the accuracy is +/- 10 meters.
Last Updated – Shows the last time this port was tested.
◆
– 173 –
| Interface Configuration
C
5
HAPTER
Port Configuration