Checking parameters changed from their initial values (Initial value change list)

5.17
Checking parameters changed from their
initial values (Initial value change list)
Parameters changed from their initial values can be displayed.
Screen at power-ON
1.
The monitor display appears.
Parameter setting mode
2.
Press
to choose the parameter setting mode. (The parameter number read previously appears.)
Selecting the parameter number
3.
Turn
to
"
" appears.
Checking the initial value change list
Turn
. The parameter numbers that have been changed from their initial value appear in order.
If
is pressed with parameters that have been changed, the parameter settings can be changed as they are. (Parameter
4.
numbers are no longer displayed in the list when they are returned to their initial values.)
Other changed parameters appear by turning
"
" is returned to when the last changed parameter is displayed.
NOTE
• Calibration parameters (C0 (Pr.900) to C7 (Pr.905), C42 (Pr.934) to C45 (Pr.935)) are not displayed even when these are
changed from the initial settings.
• Only the simple mode parameters are displayed when the simple mode is set (Pr.160 ="9999").
• Only user groups are displayed when user groups are set (Pr.160 = "1").
• Pr.160 is displayed independently of whether the setting value is changed or not.
• Parameter setting using the initial value change list is also possible.
Operation
(Initial value change list), and press
.
.
PARAMETERS
5