(M) Monitor display and monitor output signal
Monitor display (setting) increments
• When both Pr.37 and Pr.144 have been set, their priorities are as given below.
Pr.144 = 102 to 112 > Pr.37 = 1 to 9998 > Pr.144 = 2 to 12
• The combination of the Pr.37 and Pr.144 settings as shown below determines the setting increment for each monitor. (The
initial values are shown within the thick lines.)
Pr.37
Pr.144
Setting
Setting
0
0
(initial
2 to 12
value)
102 to 112
0
1 to 9998
2 to 12
102 to 112

Motor speed r/min conversion formula: .... frequency 120 / number of motor poles (Pr.144)
Machine speed conversion formula: ......... Pr.37 frequency / Pr.505
For Pr.144 in the above formula, the value is "Pr.144 - 100" when "102 to 112" is set in Pr.144; and the value is "4" when Pr.37 = 0 and Pr.144
= 0.
Pr.505 is always set as frequency (Hz).
NOTE
• The inverter's output frequency is displayed as synchronous speed under V/F control. The displayed value is "actual motor
speed" + "motor slip." When Advanced magnetic flux vector control or PM motor control is selected, the actual motor speed
(estimated value by motor slip calculation) is used.
• When Pr.37 = "0" and Pr.144 = "0", the running speed monitor is displayed with the number of motor poles 4. (Displays 1800
r/min at 60 Hz)
• To change the PU main monitor (PU main display), refer to Pr.52.
• When using the machine speed display for the parameter unit (FR-PU07), do not change the speed with the up/down key if a
set speed above 65535 is being displayed. The set speed may become an undetermined value.
• When the FR-A8ND is connected, the frequency display (setting) will be used regardless of the Pr.37, Pr.144 settings.
Caution
 Make sure to set the running speed and the number of motor poles.
Otherwise, the motor might run at extremely high speed, damaging the machine.
Parameters referred to
???????
Pr.1 Maximum frequency
Pr.52 Operation panel main monitor selection
Pr.81 Number of motor poles
Pr.800 Control method selection
262
PARAMETERS
Output frequency
monitor
0.01 Hz
0.01 Hz
1 r/min

0.01 Hz
1 (machine speed
)

0.01 Hz
page 245
page 263
page 143
page 143
Set frequency monitor
0.01 Hz
1 r/min
0.01 Hz
1 r/min
1 r/min
1 r/min

0.01 Hz
1 (machine speed
1 (machine speed
)
1 (machine speed

0.01 Hz
1 r/min
Running speed
Frequency setting
monitor
parameter setting
0.01 Hz

0.01 Hz

1 r/min

)
0.01 Hz

)
1 (machine speed

0.01 Hz


)
