Pr.
Register
C40 (933)
41933
Terminal 4 gain command (torque)
42123
Terminal 4 gain (torque)
C41 (933)
Terminal 4 gain (torque)
43933
(terminal analog value)
C42 (934)
41934
PID display bias coefficient
42124
PID display bias analog value
C43 (934)
PID display bias analog value
43934
(terminal analog value)
C44 (935)
41935
PID display gain coefficient
42125
PID display gain analog value
C45 (935)
PID display gain analog value
43935
(terminal analog value)
1000 to
45000 to
For details on parameter names, refer
1999
45999
to the parameter list
• Faults history
Register
Definition
40501
Faults history 1
40502
Faults history 2
40503
Faults history 3
40504
Faults history 4
40505
Faults history 5
40506
Faults history 6
40507
Faults history 7
40508
Faults history 8
• Model information monitor
Register
44001
Model (First and second characters)
44002
Model (Third and fourth characters)
44003
Model (Fifth and sixth characters)
44004
Model (Seventh and eighth characters)
44005
Model (Ninth and tenth characters)
44006
Model (Eleventh and twelfth characters)
44007
Model (Thirteenth and fourteenth characters)
44008
Model (Fifteenth and sixteenth characters)
44009
Model (Seventeenth and eighteenth characters)
44010
Model (Nineteenth and twentieth characters)
44011
Capacity (First and second characters)
44012
Capacity (Third and fourth characters)
44013
Capacity (Fifth and sixth characters)
NOTE
• When a 32-bit parameter setting or monitored value is read and the read value exceeds HFFFF, the reply data will be HFFFF.
Name
(page
112).
Read/Write
Read/Write
Read
Read
Read
Read
Read
Read
Read
Definition
(N) Operation via communication and its settings
Read/
Write
Read/
Write
Read/
Analog value (%) set to C41 (933)
Write
Read
Analog value (%) of current (voltage) applied to terminal 4
Read/
Write
Read/
Analog value (%) set to C43 (934)
Write
Read
Analog value (%) of current (voltage) applied to terminal 4
Read/
Write
Read/
Analog value (%) set to C45 (935)
Write
Read
Analog value (%) of current (voltage) applied to terminal 4
Read/
The parameter number + 44000 is the register number.
Write
Remarks
Data is 2 bytes and so is stored in "H00".
The lowest 1 byte can be referred to for the error code.
(For details on error codes, refer to
The faults history is batch-cleared by writing to register
40501.
Set any value for the data.
Read/Write
Read
Read
Read
Reading inverter type in ASCII code.
Read
"H20" (blank code) is set for blank area.
Read
Example of FR-F840-1 (FM type)
Read
H46, H52, H2D, H46, H38, H34, H30,
Read
H2D, H31, H20......H20
Read
Read
Read
Reading inverter capacity in ASCII code.
Read
Data is read in increments of 0.1 kW, and
rounds down to 0.01 kW increments.
Read
"H20" (blank code) is set for blank area.
Example
0.75K ........."7"
Read
(H20, H20, H20, H20, H20, H37)
Remarks
page
533.)
Remarks
PARAMETERS
5
GROUP
N
477