Mitsubishi Electric FR-F800 Instruction Manual page 292

Hide thumbs Also See for FR-F800:
Table of Contents

Advertisement

Setting
Signal
Positive
Negative
name
logic
logic
200
300
FDN2
Second PID lower limit
201
301
FUP2
Second PID upper limit
Second PID forward/reverse
202
302
RL2
rotation output
Second During PID control
203
303
PID2
activated
SLEEP
During second PID output
204
304
2
shutoff
205
305
Y205
Second PID deviation limit
Cooling fan operation
206
306
Y206
command signal
Control circuit temperature
207
307
Y207
signal
208
308
PS
PU stopped signal
Upper limit warning
211
311
LUP
detection
Lower limit warning
212
312
LDN
detection
During load characteristics
213
313
Y213
measurement
215
315
Y215
During cleaning
9999
No function

Take caution when changing the frequency setting with an analog signal or the setting dial of the operation panel (FR-DU08), because this
change speed and the timing of the change speed determined by the acceleration/deceleration time setting may cause the output of the SU (up
to frequency) signal to switch repeatedly between ON and OFF. (This repeating does not occur when the acceleration/deceleration time setting
is "0 s".)

The setting is available only for standard models.

This signal cannot be assigned to the output terminals for plug-in options (FR-A8AY, FR-A8AR).

Available when the plug-in option is connected.

When the power is reset, the fault output 2 signal (ALM2) turns OFF at the same time as the power turns OFF.
NOTE
• The same function may be set to more than one terminal
• The terminal conducts during function operation when the setting is "0 to 99, 200 to 299", and does not conduct when the
setting is "100 to 199, 300 to 399".
• When Pr.76 Fault code output selection = "1", the output signals of terminals SU, IPF, OL and FU operate according to
Pr.76 setting. (When the inverter's protective function is activated, the signal output switches to fault code output.)
• The outputs of terminal RUN and the fault output relay are assigned according to the settings above, regardless of Pr.76.
• Changing the terminal assignment using Pr.190 to Pr.196 (output terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
• Do not assign signals which repeat frequently between ON and OFF to terminals A1B1C1 or A2B2C2. The life of the relay
contacts will be shortened.
Function
Output when the value is lower than the lower limit
of second PID control.
Output when the value is higher than the upper
limit of second PID control.
Output during forward rotation under second PID
control.
Output during second PID control.
Output during second PID output suspension
function operation.
Output when the absolute deviation value during
second PID control exceeds the limit value.
Output when the cooling fan operation is
commanded.
Output when the temperature of the control circuit
board reaches the detection level or higher.
Output while the PU is stopped.
Output when the load fault upper limit warning is
detected.
Output when the load fault lower limit warning is
detected.
Output during measurement of the load
characteristics.
Output during operation of the cleaning function.
(M) Monitor display and monitor output signal
Operation
Refer
Related
to
parameter
page
Pr.753 to Pr.758
Pr.753 to Pr.758
378
Pr.753 to Pr.758,
Pr.1147 to Pr.1149
Pr.753 to Pr.758,
Pr.1145, Pr.1146
Pr.244
233
Pr.663
304
Pr.75
162
Pr.1480 to Pr.1492
255
Pr.1469 to Pr.1479
375
291
PARAMETERS
5
GROUP
M

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents