Ca Type - Mitsubishi Electric FR-F800 Instruction Manual

Hide thumbs Also See for FR-F800:
Table of Contents

Advertisement

CA type
Sourse logic
Main circuit terminal
Control circuit terminal
MC
MCCB
Three-phase
AC power
supply
Jumper
∗2
Earth
(Ground)
Control input signals
(No voltage input allowed)∗3
Forward rotation start
Reverse rotation start
Start self-holding selection
High speed
Multi-speed
Middle speed
selection
Low speed
Jog operation
Second function selection
Output stop
Reset
Terminal 4 input selection
(Current input selection)
∗10
Common for external power
supply transistor
Contact input common
24VDC power supply
24V external power
supply input
Common terminal
Frequency setting signals (Analog)
3
Frequency setting
2
potentiometer
1/2W1kΩ∗6
1
Auxiliary
(+)
(-)
input
Terminal 4 input
(+)
(-)
(Current input)
Connector for plug-in option connection
Safety stop signal
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Safety stop input common
DC reactor
(FR-HEL)∗1
Jumper
Jumper
Earth
(Ground)
P1
P/+
PX∗7 PR∗7 N/-
R/L1
Inrush current
S/L2
limit circuit
T/L3
ON
EMC filter
R1/L11
ON/OFF
connecter
S1/L21
OFF
Main circuit
Control circuit
STF
STR
STP(STOP)
RH
RM
RL
∗4
JOG
RT
MRS
RES
AU
CS
SD
24V
PC
+24
SD
Voltage/current
∗5
input switch
ON
10E(+10V)
OFF
10(+5V)
2
4
DC0 to 5V
Initial value
2
DC0 to 10V selectable
DC0 to 20mA
5
(Analog common)
Initial value
DC0 to ±10V
1
∗5
DC0 to ±5V selectable
DC4 to 20mA
Initial value
4
DC0 to 5V
selectable
∗5
DC0 to 10V
connector 1 connector 2
connector 3
Shorting
24V
wire
PC
S1
Output shutoff
S2
circuit
SIC
SD
Terminal connection diagrams
FR-F820-00770(18.5K) to 01250(30K),
FR-F840-00470(22K) to 01800(75K)
Brake unit
(Option)
Earth
(Ground)
U
V
W
C1
B1
Relay output 1
(Fault output)
A1
C2
B2
Relay output 2
A2
RUN
Open collector output∗9
Running
SU
Up to frequency
IPF
Instantaneous
power failure
OL
Overload
FU
Frequency detection
SE
Open collector output common
Sink/source common
PU
connector
F/C
(+)
(CA)
USB A
(-)
connector
∗5
USB
AM
(+)
mini B
connector
(-)
5
TXD+
TXD-
RXD+
RXD-
SG
Terminating
5V
VCC
resistor
(Permissible load current 100mA)
So
Safety monitor output
SOC
Safety monitor output common
INSTALLATION AND WIRING
DC reactor
(FR-HEL)∗1
Brake unit
(Option)
Jumper
P1
P/+
P3
PR∗7 N/-
Motor
M
Earth (Ground)
Relay output∗8
Analog current output
(0 to 20mADC)
Analog signal output
(DC0 to ±10V)
RS-485 terminals
Data
transmission
Data
reception
GND
2
35