Common Specifications - Mitsubishi Electric FR-F800 Instruction Manual

Hide thumbs Also See for FR-F800:
Table of Contents

Advertisement

8.3

Common specifications

Control method
Output frequency range
Frequency
Analog input
setting
resolution
Digital input
Frequency
Analog input
accuracy
Digital input
Voltage/frequency
characteristics
Induction
Starting
motor
torque
IPM motor
Torque boost
Acceleration/deceleration
time setting
DC injection brake
(induction motor)
Stall prevention operation
level
Frequency
Analog input
setting
Digital input
signal
Start signal
Input signals (twelve
terminals)
Pulse train input
Operational functions
Output signal
Open collector output (five
terminals)
Relay output (two
terminals)
Pulse train output
Pulse train
output (FM
type)
Current
For meter
output
(CA type)
Voltage
output
Operating
Operation
status
panel
(FR-DU08)
Fault record
Protective
function
Protective/
warning
function
Warning
function
Soft-PWM control, high carrier frequency PWM control (selectable among V/F control (Optimum excitation control),
Advanced magnetic flux vector control (Advanced optimum excitation control) and PM motor control)
0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control, and PM motor control.)
0.015 Hz/60 Hz (terminal 2, 4: 0 to 10 V/12 bits)
0.03 Hz/60 Hz (0 to 5 V/11 bits or 0 to 20 mA/approx. 11 bits for terminals 2 and 4, 0 to 10 V/12 bits for terminal 1)
0.06 Hz/60 Hz (0 to 5 V/11 bits for terminal 1)
0.01 Hz
Within 0.2% of the max. output frequency (25°C 10°C)
Within 0.01% of the set output frequency
Base frequency can be set from 0 to 590 Hz. Constant-torque/variable-torque pattern or adjustable 5 points V/F can be
selected.
120% 0.5 Hz (Advanced magnetic flux vector control)
50%
Manual torque boost
0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode,
backlash countermeasures acceleration/deceleration can be selected.
Operation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30%) variable
Activation range of stall prevention operation (SLD rating: 0 to 120%, LD rating: 0 to 150%). Whether to use the stall
prevention or not can be selected. (V/F control, Advanced magnetic flux vector control)
Terminals 2 and 4: 0 to 10 V, 0 to 5 V, 4 to 20 mA (0 to 20 mA) are available.
Terminal 1: -10 to +10 V, -5 to 5 V are available.
Input using the setting dial of the operation panel or the parameter unit
Four-digit BCD or 16-bit binary (when used with option FR-A8AX)
Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Low-speed operation command, Middle-speed operation command, High-speed operation command, Second function
selection, Terminal 4 input selection, Jog operation selection, Output stop, Start self-holding selection, Forward rotation
command, Reverse rotation command, Inverter reset
The input signal can be changed using Pr.178 to Pr.189 (input terminal function selection).
100 kpps
Maximum and minimum frequency settings, multi-speed operation, acceleration/deceleration pattern, thermal protection,
DC injection brake, starting frequency, JOG operation, output stop (MRS), stall prevention, regeneration avoidance,
increased magnetic excitation deceleration, DC feeding
instantaneous power failure, electronic bypass sequence, remote setting, retry function, carrier frequency selection, fast-
response current limit, forward/reverse rotation prevention, operation mode selection, slip compensation, speed
smoothing control, traverse, auto tuning, applied motor selection, RS-485 communication, PID control, PID pre-charge
function, cooling fan operation selection, stop selection (deceleration stop/coasting), power-failure deceleration stop
function, PLC function, life diagnosis, maintenance timer, current average monitor, multiple rating, test run, 24 V power
supply input for control circuit, safety stop function, self power management, BACnet communication, PID gain tuning,
cleaning, load characteristics storage, emergency drive
Inverter running, Up to frequency, Instantaneous power failure/undervoltage
detection, Fault
The output signal can be changed using Pr.190 to Pr.196 (output terminal function selection).
Fault codes of the inverter can be output (4 bits) from the open collector.
50 kpps
Max. 2.4 kHz: one terminal (output frequency)
The monitored item can be changed using Pr.54 FM/CA terminal function selection.
Max. 20 mADC: one terminal (output current)
The monitored item can be changed using Pr.54 FM/CA terminal function selection.
Max. 10 VDC: one terminal (output voltage)
The monitored item can be changed using Pr.158 AM terminal function selection.
Output frequency, output current, output voltage, frequency setting value
The monitored item can be changed using Pr.52 Operation panel main monitor selection.
Fault record is displayed when a fault occurs. Past 8 fault records and the conditions immediately before the fault (output
voltage/current/frequency/cumulative energization time/year/month/date/time) are saved.
Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop,
Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative
overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip
(electronic thermal relay function), Heatsink overheat, Instantaneous power failure
Stall prevention stop, Loss of synchronism detection
earth (ground) fault overcurrent, Output phase loss, External thermal relay operation
fault, Communication option fault, Parameter storage device fault, PU disconnection, Retry count excess
Operation panel power supply short circuit/RS-485 terminals power supply short circuit, 24 VDC power fault, Abnormal
output current detection
, Inrush current limit circuit fault

communication fault, Safety circuit fault, Overspeed occurrence
Internal circuit fault, User definition error in the PLC function
Fan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Electronic thermal relay function pre-alarm, PU
stop, Parameter copy, Safety stop, Maintenance timer 1 to 3
locked
, Parameter write error, Copy operation error, 24 V external power supply operation, Load fault warning,

Emergency drive in operation
Common specifications
, frequency jump, rotation display, automatic restart after

, Overload warning, Output frequency

, Undervoltage

, Upper limit fault detection, Lower limit fault detection, Output side

, PTC thermistor operation

, Communication fault (inverter), Analog input fault, USB

, 4 mA input fault
, Pre-charge fault


, USB host error, Operation panel lock

SPECIFICATIONS
, Input phase loss
,


, Option

, CPU fault,

, PID signal fault
,


, Password

8
583

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents