Parameter List (By Function Group); Environment Setting Parameters; Setting Of Acceleration/Deceleration Time And Acceleration/Deceleration Pattern; Operation Command And Frequency Command - Mitsubishi Electric FR-F800 Instruction Manual

Hide thumbs Also See for FR-F800:
Table of Contents

Advertisement

Parameter List

Parameter list (by function group)

5.1.3
Parameter list (by function group)
 E: Environment setting parameters
Parameters that set the inverter operation characteristics.
Pr.
Pr.
group
E000
168
Parameter for manufacturer setting. Do not set.
E001
169
Parameter for manufacturer setting. Do not set.
E020
1006
Clock (year)
E021
1007
Clock (month, day)
E022
1008
Clock (hour, minute)
E023
269
Parameter for manufacturer setting. Do not set.
E080
168
Parameter for manufacturer setting. Do not set.
E081
169
Parameter for manufacturer setting. Do not set.
E100
75
Reset selection
E101
75
Disconnected PU detection
E102
75
PU stop selection
E103
145
PU display language selection
E104
990
PU buzzer control
E105
991
PU contrast adjustment
E106
1048
Display-off waiting time
E107
75
Reset limit
E108
1000
Parameter for manufacturer setting. Do not set.
E110
1049
USB host reset
Frequency setting/key lock operation
E200
161
selection
Frequency change increment amount
E201
295
setting
E300
30
Regenerative function selection
E301
570
Multiple rating setting
E302
977
Input voltage mode selection
E400
77
Parameter write selection
E410
296
Password lock level
E411
297
Password lock/unlock
E420
888
Free parameter 1
E421
889
Free parameter 2
E430
998
PM parameter initialization
E431
999
Automatic parameter setting
E440
160
User group read selection
User group registered display/batch
E441
172
clear
E442
173
User group registration
E443
174
User group clear
E490
989
Parameter copy alarm release
E600
72
PWM frequency selection
E601
240
Soft-PWM operation selection
E602
260
PWM frequency automatic switchover
E700
255
Life alarm status display
E701
256

Inrush current limit circuit life display
E702
257
Control circuit capacitor life display
E703
258

Main circuit capacitor life display
E704
259

Main circuit capacitor life measuring
E710
503
Maintenance timer 1
Maintenance timer 1 warning output set
E711
504
time
E712
686
Maintenance timer 2
Maintenance timer 2 warning output set
E713
687
time
E714
688
Maintenance timer 3
134
PARAMETERS
Refer
Name
to page
160
160
160
162
162
162
164
164
165
165
162
540
166
167
508
168
168
169
171
171
173
173
Simple
Simple
Simple
149
Simple
Simple
Simple
173
Simple
Simple
Simple
177
177
177
177
521
179
179
179
180
180
180
180
180
184
184
184
184
184
Pr.
Pr.
group
Maintenance timer 3 warning output set
E715
689
time
E720
555
Current average time
E721
556
Data output mask time
Current average value monitor signal
E722
557
output reference current
 F: Setting of acceleration/deceleration time and
acceleration/deceleration pattern
Parameters that set the motor acceleration/deceleration
characteristics.
Pr.
Pr.
group
Acceleration/deceleration reference
F000
20
frequency
Acceleration/deceleration time
F001
21
increments
F002
16
Jog acceleration/deceleration time
F003
611
Acceleration time at a restart
F010
7
Acceleration time
F011
8
Deceleration time
F020
44
Second acceleration/deceleration time
F021
45
Second deceleration time
Acceleration/deceleration time
F022
147
switching frequency
F040
1103
Deceleration time at emergency stop
F070
791
Acceleration time in low-speed range
F071
792
Deceleration time in low-speed range
Acceleration/deceleration pattern
F100
29
selection
F101
59
Remote function selection
F102
13
Starting frequency
F103
571
Holding time at a start
Backlash acceleration stopping
F200
140
frequency
F201
141
Backlash acceleration stopping time
Backlash deceleration stopping
F202
142
frequency
F203
143
Backlash deceleration stopping time
 D: Operation command and frequency
command
Parameters that specify the inverter's command source, and
parameters that set the motor driving frequency and torque.
Pr.
Pr.
group
D000
79
Operation mode selection
D001
340
Communication startup mode selection
Communication operation command
D010
338
source
Communication speed command
D011
339
source
NET mode operation command source
D012
550
selection
PU mode operation command source
D013
551
selection
D020
78
Reverse rotation prevention selection
D100
291
Pulse train I/O selection
D101
384
Input pulse division scaling factor
D110
385
Frequency for zero input pulse
Refer
Name
to page
184
185
185
185
Refer
Name
to page
187
187
221
414,
420
187
Simple
Simple
Simple
Simple
Simple
Simple
187
187
187
187
187
187
187
191
194
197,
198
197
191
191
191
191
Refer
Name
to page
200,
Simple
Simple
Simple
209
209
210
210
210
210
217
218,
273
218
218