(D) Operation command and frequency command
Operation at fault
Conditions
Fault record
(Pr.551 setting)
Inverter fault
―
2 (PU connector)
9999 (automatic
PU connector
recognition)
disconnection
Other than 2
Communication
2 (PU connector)
error at PU
connector
Other than 2
1 (RS-485
Communication
terminals)
error at RS-485
terminals
Other than 1
3 (USB
connector)
Communication
9999 (automatic
error at USB
recognition)
connector
Other than 3
Communication
error at
―
communication
option
Selectable with Pr.75 Reset selection/disconnected PU detection/PU stop selection
Selectable with Pr.122 PU communication check time interval, Pr.336 RS-485 communication check time interval, and Pr.548 USB
communication check time interval
Follows the communication option
In the PU JOG operation mode, operation always stops when the PU is disconnected. The operation of PU disconnection (E.PUE) follows the
Pr.75 Reset selection/disconnected PU detection/PU stop selection setting.
When Pr.550 NET mode operation command source selection= "1" (RS-485 terminals enabled), or Pr.550 NET mode operation command
source selection="9999" with no communication option connected.
When Pr.550 NET mode operation command source selection="0" (communication option enabled), or Pr.550 NET mode operation
command source selection="9999" with communication option connected.
214
PARAMETERS
Operation in each operation mode at error occurrences
PU
External
operation
operation
Stop
Stop/continued
Stop/continued
Stop/continued
Continued
Continued
Stop/continued
Continued
Continued
Stop/continued
Continued
Continued
Continued
External/PU
External/PU
combined
combined
operation
operation
mode 1
mode 2
(Pr.79 =3)
(Pr.79 =4)
Stop/
continued
Stop/
continued
NET
NET operation
operation
(when
(when RS-485
communication
terminals are
option is
used)
used)
Continued
Continued
Stop/continued
Continued
Stop/continued