2.4.2
Areas 1 and 2 – Control Bay Metering
Date printed: 27.0.0
Control Bay Meters
The METER VIEW selector keys allow selecting from:
FOLLOW – the same meter view as is shown on the fader bays, for the
ten channels that are currently assigned on the control bay
• AUX, GROUPS, MASTER, DIR OUT, BUS OUT, N–1, and MATRIX
• Four USER pages:
USER 1: A master meter page with space for 10 channel meters (1 row)
USER 2: A master meter page with space for 20 channel meters (2 rows)
USER 3 and USER 4: Master meter pages with space for 40 channel meters
(2 rows, at half width).
The meter selections shown with the USER 1...4 keys can be defined in the
GC strip setup page.
PFL and (CR) Monitoring meters are displayed at the far right in the USER
1...4 pages.
Label Area
Displays the inherited label of the assigned channel or of the monitored
signal.
OVERLOAD: HOLD
Activates the hold function for all overload LEDs in the console. If active,
even overloads in sections that are currently not visible are held. Therefore it
is possible to scroll through the sections and check whether overloads have
occurred.
OVERLOAD: OVER RESET
The overload indicators display clipping of any DSP core output interface.
Since the DSP core holds all audio in floating-point format, basically no clip-
ping can occur within the core. Clipping only occurs when sending a signal
through a 24-bit output interface. Therefore, this indicators show real clipping
somewhere on an output.
If OVERLOAD: HOLD is on, this LED is held as well. Pressing this key will
reset all held overloads.
PEAK: HOLD
Toggles the peak hold function through off, TEMP (temporary hold), and CONT
(continuous hold).
Channels with a continuous peak hold condition will indicate the amount
of dB above clipping level in the generic display area of the Vistonics™
screen.
PEAK: RESET
Pressing this key will reset the peak hold indication, if continuous hold has
been activated with PEAK: HOLD.
SW V4.5
Vista 9 Digital Mixing System
Desk Operation 2-7