3.4.2

Dynamics Parameters

3.4.2.1

standard Dynamics

Limiter Parameters:
LIM on/off Limiter on/off.
LIM ThRs Rotary The limiter threshold (= output level) can be adjusted in 1 dB steps from 0 dB
LIM ReL Rotary The limiter release time can be adjusted in 13 steps within a 10 ms to 10 s
LIM hold on/off Hold on = 150 ms, off = 0 ms.
LIM aTCK Rotary The limiter attack time can be adjusted in 9 steps within a 200 µs to 1 ms
Output level
[dBFS]
0
–5
–10
–15
–20
–25
–30
–35
–40
–45
–50
–55
–60
–65
–70
–75
–80
–85
–90
–90
–80
–70
–60
–50
–40
–30
3-2 Parameters
–48 dB
.
FS
range (10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms, 300 ms, 500 ms, 1 s,
2 s, 3 s, 5 s, and 10 s).
range (0.2 ms, 0.3 ms, 0.4 ms, 0.5 ms, 0.6 ms, 0.7 ms, 0.8 ms, 0.9 ms, and
1
1 ms).
Curve
2
1
3
1
2
4
3
4