Isolate - Studer Vista 9 Operating Instructions Manual

Digital mixing system, sw v4.5
Table of Contents

Advertisement

Auto­matio­n Menu • Selecting 'Clear TRIM Replay Data' from the Automation menu in the
Entering TRIM RECORD Controls in TRIM ENABLE can change to TRIM RECORD using any of the
5.6.4

isolate

ISOLATE Rules Reco­rd Off:
Date printed: 28.0.0
GC deletes the fader Trim Replay Data and creates a new Mix Pass with
0 dB recorded as the new Trim Replay value.
following 3 methods:
1. Local Touch (Touching the control on the Channel Strip) or CGM
Touch. TOUCH RECORD engaged or the AUTO MODE modifier key
must be used.
2. Local punch-in using the Channel Strip STAT (record punch) key.
3. Global punch-in via Global Record PUNCH-IN key, or Auto-Punch,
or GPI (refer to chapter 5.8.5).
ISOLATE is the system's manual mode. Controls in ISOLATE neither re-
sponds to or creates new mix data. In other words, the control is essentially
removed from the automation system is becomes strictly a manual control.
No­te A control in ISOLATE mode differs from a Static control in regard that
changes in an Isolated control's position are not written to Mix Passes. Like-
wise, Static values are not applied to Isolated controls.
• ISOLATE: The control acts like a manual control and is unaffected by any
previously written Read and Trim Replay data.
-
The audio follows the control position
Reco­rd On:
• A control in ISOLATE cannot be placed into record.
SW V4.5