5.10.3.3 modified Press Function

5-84 AutoTouch+
It is possible to suppress the toggle function when a switch is pressed, but still
allow the Touch event to be produced. This allows a punch-in or Audition to
be performed by pressing a switch without toggling its state. This 'Modified
Press Function' is very useful when the punch-in switch state matches the
Read Mix state.
This Modified Press Function is available for both Press and Release and
Press and Hold operations.
The key press may be modified by holding the AUTO MODE key while a work
surface key is pressed. In this regard, the AUTO MODE key functions as a
modifier key.
Example With Touch Record engaged, press and hold the AUTO MODE key, then press
and hold a record-enabled key. When the key is pressed, it will punch-in but
its status will not toggle. If the AUTO MODE key is released before the key is,
toggle suppression is turned off. Now when the key is released, it will toggle
its status, and the key release will cause the control to punch-out.