Modified Un-Touch Inverts; Option Modified Un-Touch Inverts <Touch Record - Studer Vista 9 Operating Instructions Manual

Digital mixing system, sw v4.5
Table of Contents

Advertisement

Vista 9 Digital Mixing System
5.7.6.1

modified un-touch inverts

5.7.6.1.1
Option Modified Un-Touch Inverts <Touch Record>
Both Glo­bal TOUCH RECORD and Glo­bal TOUCH HELD inactive:
Glo­bal TOUCH RECORD active, Glo­bal TOUCH HELD inactive:
Glo­bal TOUCH RECORD inactive, Glo­bal TOUCH HELD active:
5-0 AutoTouch+
As an option, TOUCH RECORD or TOUCH HELD may have their modified
Un-touch function inverted. In other words, if the AUTO MODE key is held
down when a control is Un-touched (released) the normal Un-touch function
of Touch Record or Touch Hold will be reversed.
Either Touch Record or Touch Hold may be selected for Un-touch inversion,
but not both.
<Optio­n> • Either the TOUCH HELD or TOUCH RECORD function may be selected
for Modified Un-touch Inversion when the AUTO MODE key is held. This
selection is made by clicking the desired radio button in the <Modified
Un-touch Inverts> section of the Misc Options page (also refer to chapter
5.21.7).
1a Holding the AUTO MODE key when an enabled control is touched, will punch
that control in RECORD. As long as the AUTO MODE key is held down, a
touched control will be in RECORD. Un-touching the control will return the
status from RECORD to ENABLE.
1b If the control is touched and the AUTO MODE key is released before the con-
trol is physically un-touched, the control will remain in RECORD even if the
control is physically un-touched.
Even if the control remains in RECORD, the un-touch information is sup-
pressed.
1c A control being in RECORD can be punched out by holding the AUTO MODE
key, and touching and un-touching the control while the AUTO MODE key is
being pressed. The control changes from RECORD to ENABLE when the
control is physically un-touched.
2a While pressing the AUTO MODE key, touching of a control that is in ENABLE
mode will not punch it into RECORD.
2b Touching the control (causing it to change from ENABLE to RECORD) and
pressing the AUTO MODE key while still touching the control, then releasing
the control while still pressing the AUTO MODE key will cause the control to
remain in RECORD and HELD status.
3a Keep the AUTO MODE key pressed. Touching and untouching a control in
ENABLE mode will punch the control in and out of RECORD. Please note
that the control is in HELD status, regardless whether it is in RECORD or
not.
3b Keep the AUTO MODE key pressed and touch a control that is currently in
ENABLE mode. Keep the control touched and release the AUTO MODE key.
The control will remain in RECORD.
3c A control being in RECORD mode can be punched out by keeping the AUTO
MODE key pressed, then touching and un-touching the control. At the moment
the control is released, it punches out of RECORD but remains in HELD
status.