To­uch Reco­rd + To­uch Ho­ld With both TOUCH RECORD and TOUCH HOLD engaged, Touch events perform
5.7.5

Held Controls

Held Co­ntro­ls Buffer As controls are placed into a held status, they are added to a list of controls
Clearing Held Co­ntro­ls Clear Held Controls Buffer: Pressing the CLR HELD key will take all Held
Date printed: 28.0.0
the following functions when dynamic controls are in the Control Modes
indicated (remember Un-touch events are suppressed):
• READ: Touch will change to and stay in AUDITION.
• WRITE ENABLE: Touch will change the control from WRITE ENABLE
to WRITE RECORD and stay in WRITE RECORD when released.
• TRIM ENABLE: Touch will change the control from TRIM ENABLE to
TRIM RECORD and stay in TRIM RECORD when released.
• ISOLATE: Touch/Un-touch events of Isolated controls are not recognized
by AutoTouch+.
<Optio­n> • With <Read Safe> checked on the Misc Options page (see chapter 5.21.7),
AUDITION mode is defeated for controls in READ, and only written
values will be heard.
• The Master Panel TOUCH RECORD and TOUCH HOLD keys may be over-
ridden by checking options on the <Master Panel Overrides> section of
the Master Panel Options page (see chapter 5.21.5). Faders and Encoders
can have TOUCH RECORD and TOUCH HOLD set to <ON>, <OFF>, or to
follow the Master Panel <Follows Panel>. TOUCH RECORD and TOUCH
HOLD for Switches can also have <ON> and <OFF> overrides or be set to
follow the Master Panel <Follows Panel>
• The Un-touch function of either TOUCH RECORD or TOUCH HOLD may
be changed by using the AUTO MODE modifier key. For details, refer to
chapter 5.7.6.
A control that is touched with TOUCH HOLD engaged becomes a 'held' con-
trol. Held controls are also known as 'Held Objects.' Controls that are held
not only stay in their Touched mode when released, they are identified by the
system as being held.
stored in the 'Held Controls Buffer.' The CLR HELD key in the HELD section
of the AutoTouch+ Panel will light if one or more control is held.
The Held Controls list is used as a filter for the HELD preselectors in the
Control Modes and Global Record sections of the Automation Panel.
controls out of Hold. It will also clear the list of controls in the Held Controls
Buffer.
Clear Held Controls Modes: Controls may be taken out of hold in the fol-
lowing ways:
• When TOUCH HOLD is turned OFF <Optio­n>
• Upon Punch-Out <Optio­n>
• At the end of a Mix Pass <Optio­n>
<Optio­n> • With <When Touch Hold Turned Off> checked in the <Clear Held Objects>
section of the Hold Options page (also refer to chapter 5.21.4), all held
controls are cleared when TOUCH HOLD is turned Off.
• With <Upon Punch-Out> checked in the <Clear Held Objects> section of
the Hold Options page, any Held control is cleared upon punch-out.
• With <Held Objects> checked in the <End of Pass Clears> section of the
End of Pass Options page, all held controls are cleared at the end of each
Mix Pass.