Avaya DEFINITY Server CSI Maintenance Manual page 1678

Table of Contents

Advertisement

Maintenance Objects
Hardware Error Log Entries and Test to Clear
Values
Table 494. DS1 Tie Trunk Error Log Entries
Error
Aux
Type
Data
1
0
0
1 (a)
57476
57477
57485
57487
15 (b)
Any
18 (c)
0
19(d)
0
130 (e)
257 (f)
57473
57474
513(g)
57392
769(h)
57393
1025
1281
1537
1793 (i)
2305(j)
50944
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2.
This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are
out of service, then the alarm will be upgraded to a MAJOR alarm.
3.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set
options command. If the MINOR alarm is not downgraded by the set options values, the MINOR alarm
is upgraded to a MAJOR alarm if 75 percent of the trunks in this trunk group are alarmed.
1678
Issue 5 October 2002
Associated Test
Any
Any
Port Audit and
Update Test (#36)
busyout trunk
WARNING
<grp>/<mbr>
None
None
WARNING
DS1 Tie Trunk
MIN/MAJ
Seizure Test (#136)
DS1 Tie Trunk
MIN/MAJ
Seizure Test (#136)
DS1 Tie Trunk
MAJ/MIN/
Seizure (Test #136)
WRN
Conference Circuit
MAJ/MIN/
(Test #7)
WRN
NPE Crosstalk Test
MAJ/MIN/
(#6)
WRN
DS1 Tie Trunk
MIN/MAJ
Seizure Test (#136)
Alarm
On/Off
Level
Board
Any
OFF
ON
2
2
OFF
3
ON
3
ON
3
3
OFF
Test to Clear Value
test trunk <grp>/<mbr> sh
r 1>
release trunk <grp>/<mbr>
test trunk <grp>/<mbr>
test trunk <grp>/<mbr> r 2
test trunk <grp>/<mbr> l r
4
test trunk <grp>/<mbr> l r
3
test board PCSS long
Continued on next page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents