Avaya DEFINITY Server CSI Maintenance Manual page 1702

Table of Contents

Advertisement

Maintenance Objects
Table 501. TEST #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
2000
ABORT
2100
ABORT
Any
FAIL
PASS
0
NO
BOARD
1702
Issue 5 October 2002
Description/ Recommendation
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
This test can fail due to on-board or off-board problems. Off-board problems
of concern include TDM-BUS faults and faults associated with the tone
detectors/tone generators. Clear all off-board problems before replacing the
board. Keep in mind that a TDM-BUS problem is usually the result of a
faulty board connected to the backplane or bent pins on the backplane.
1. Look for TDM-BUS errors in the error log. If present, refer to the
TDM-BUS Maintenance documentation.
2. Look for TONE-BD and/or TONE-PT errors in the error log. If present,
refer to the TONE-BD Maintenance documentation and the TONE-PT
Maintenance documentation.
3. Test the board when the faults from steps 1 and 2 are cleared. Replace
the board only if the test fails.
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and examining
station, trunk or external wiring.
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Continued on next page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents