TIME-DAY (Time of Day)
To resolve the alarm, do the following:
1. Use the set time command to set the time of day.
2. Use the display time command to display the time of day. If the time of day
is displayed correctly, wait 15 minutes and verify that the alarm is retired. If
the alarm has not been retired, continue with Step 3.
3. Test the active TN1648 SYSAM circuit pack using the test maintenance [a
| b] sh command. If any tests fail, refer to the repair procedures for the
SYSAM circuit pack before further investigating time-of-day problems. If all
tests PASS and the alarm has not been retired, proceed to Step 4.
4. Replace the active TN1648 SYSAM circuit pack must be replaced. See
"Replacing SPE Circuit Packs" in Chapter 5. The alarm should be resolved
within 15 minutes of replacing the SYSAM and resetting the time with set
time.