Avaya DEFINITY Server CSI Maintenance Manual page 1697

Table of Contents

Advertisement

TIE-TRK (Tie Trunk)
Hardware Error Log Entries and Test to Clear
Values
Table 500. TIE Trunk Error Log Entries
Error
Aux
Type
Data
1
0
0
2
2
1 (a)
16384
2
2
1 (b)
57476
2
2
1 (c)
57477
1 (d)
57483
2
2
1 (e)
57485
15 (f)
Any
18 (g)
0
2
130 (h)
257 (i)
57473
257 (j)
57474
257 (k)
57475
513
Any
769
57481
2
1025 (l)
Any
3
57392
1281
Any
1537
1793
555-233-119
Associated Test
Any
Any
2
None
WARNING
2
None
WARNING
2
None
WARNING
3
None
WARNING
2
None
WARNING
Port Audit Update
(#36); Audit and
Update (#36)
busyout trunk
WARNING
<grp/mbr>
2
None
WARNING
None
WARNING
None
WARNING
None
WARNING
EPF M and E Lead
MAJ/MIN/
(#74)
WRN
EPF M and E Lead
MAJ/MIN/
(#74)
WRN
None
MAJ/MIN/
WRN
MINOR
EPF M and E Lead
MAJ/MIN/
(#74)
WRN
Loop Around and
MAJ/MIN/
Conference (#33)
WRN
MINOR
Tie Trunk Seizure
MAJ/MIN/
(#73); Seizure
WRN;
3
(#73)
; Tie Trunk
MINOR
Dial (#747)
On/Off
Alarm Level
Board
Any
2
2
OFF
2
2
OFF
2
2
OFF
OFF
2
2
OFF
OFF
ON
OFF
OFF
OFF
OFF
1
ON
1
OFF
1,2
3
ON
1
ON
1,
OFF
Issue 5 October 2002
Test to Clear Value
test port PCSSpp s r 1
release trunk <grp/mbr>
test trunk <grp>/<mbr>
test port PCSSpp sh r 3
test port PCSSpp sh r 3
test port PCSSpp sh r 3
test port PCSSpp l r 3
test port PCSSpp sh r 2;
test port PCSSpp s r 2
Continued on next page
1697

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents