Avaya DEFINITY Server CSI Maintenance Manual page 1691

Table of Contents

Advertisement

TIE-DS1 (DS1 Tie Trunk)
Table 499. TEST #136 DS1 Tie Trunk Seizure Test — Continued
Error
Test
Code
Result
1005
ABORT
1018
ABORT
1020
ABORT
1040
ABORT
2000
ABORT
2100
ABORT
2053
ABORT/
1
FAIL
555-233-119
Description/ Recommendation
Test failed due to incompatible configuration administered in trunk group
form.
1. Verify the following fields on the trunk group administration screen:
a. Is trunk direction incoming only?
b. Is trunk outgoing type either automatic or immediate-start?
c. Is trunk the 24th port of the DS1 Interface circuit pack while
common control channel signaling is specified?
2. If the trunk has been administered using the above information, then
this test should abort.
The test was disabled via translation. You may want to determine why the
test has been disabled before you enable it.
1. Verify that the
Maintenance Test
Administration screen is set to n. To enable the test, change the trunk
administration and enter y into the
2. Repeat the test.
The test did not run due to an already existing error on the specific port or
due to a more general circuit pack error.
1. Examine the error log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
2. Retry the test.
This test is not performed for trunk ports administered as access endpoints.
1. Verify this port is an access endpoint by using the display port
command.
2. If the port has been administered as an access endpoint, this test
should abort.
Response to the test request was not received within the allowable time
period.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
At least one of the following errors is found on the circuit pack: 1281: Loss
of Signal, 1793: Blue Alarm, 2049: Red Alarm, 2305: Yellow Alarm, 1537:
Hyperactivity.
1. Look for the above error types in the Hardware Error Log and follow the
procedures given in the DS1-BD tests for the listed error types.
field on the Trunk
Maintenance Test
Continued on next page
Issue 5 October 2002
field.
1691

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents