Mitsubishi Electric L26CPU-BT User Manual page 417

Melsec-l cc-link system master/local module
Hide thumbs Also See for L26CPU-BT:
Table of Contents

Advertisement

Number
Name
SB0083
Other station switch
(5E8
, b3)
change status
H
SB0090
Host line status
(5E9
, b0)
H
SB0094
Transient transmission
(5E9
, b4)
status
H
SB0095
Master station transient
(5E9
, b5)
transmission status
H
SB00B4
Standby master station test
(5EB
, b4)
result
H
SB0160
Remote register use
(5F6
, b0)
prohibited status
H
Transmission speed test
SB0184
result for standby master
(5F8
, b4)
H
station
SB0185
Transmission speed test
(5F8
, b5)
accept status
H
SB0186
Transmission speed test
(5F8
, b6)
completion status
H
*1
Can be used for the standby master station only.
*2
The other station data link status (SB0080) takes up to 6 seconds to turn on after a device station connected to the
master/local station becomes faulty.
The time to turn ON differs according to the system configuration, faulty status or other conditions.
*3
Parameter setting is required in the case of a standby master station.
*4
For the station No. 0 only.
Description
Detects changes in setting switches of other stations during data
linking.
OFF: No change
ON: Change detected.
Depending on the link refresh timing, SB0083 may be updated with
the time difference of one sequence scan from the update of the
other station switch change status (SW008C to SW008F).
Indicates the line status of the host.
OFF: Normal
ON: Abnormal (line disconnection)
Indicates whether a transient transmission error has occurred.
OFF: No error
ON: Error occurrence. (SW0094 to SW0097)
Even when a dedicated instruction was retried, an error is
detected.
Depending on the link refresh timing, SB0094 may be updated with
the time difference of one sequence scan from the update of the
transient transmission status (SW0094 to SW0097).
Indicates the transient transmission status of the master station.
OFF: Normal
ON: Abnormal
Stores the test result of loop test 1.
OFF: Normal
ON: Abnormal
Stores the use prohibited status of the remote register.
OFF: Usable
ON: Use prohibited (The status information is stored in SW0160 to
SW0163.)
Depending on the link refresh timing, SB160 may be updated with
the time difference of one sequence scan from the update of the
remote register use prohibited status (SW0160 to SW0163).
Stores a result of the transmission speed test for the standby
master station.
OFF: Normal (Same transmission speed as that of master station),
or no response from the module
ON: Abnormal (Different transmission speed from that of master
station)
Indicates the accept status of Transmission speed test request
(SB000B).
OFF: Not accepted
ON: Accepted
Indicates the completion status of the transmission speed test.
OFF: Not complete
ON: Test complete
APPENDICES
Availability
(: Available, : Not available)
Online
Offline
Master
Local
station
station
415
A

Advertisement

Table of Contents
loading

This manual is also suitable for: