Mitsubishi Electric L26CPU-BT User Manual page 18

Melsec-l cc-link system master/local module
Hide thumbs Also See for L26CPU-BT:
Table of Contents

Advertisement

Term
Programming tool
QCPU
QnACPU
Remote device station
Remote I/O net mode
Remote I/O station
Remote input (RX)
Remote module
Remote net additional mode
Remote net mode
Remote net Ver.1 mode
Remote net Ver.2 mode
Remote output (RY)
Remote register (RWr)
Remote register (RWw)
Remote station
Return
Special function module
Standby master station
Transient transmission
Ver.1-compatible device station
Ver.2-compatible device station
16
A generic term for GX Works2 and GX Developer
Another term for the MELSEC-Q series CPU module
Another term for the MELSEC-QnA series CPU module
A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic
transmission. This station cannot perform transient transmission.
A mode used to perform high-speed communications in a system consisting of a master station and
remote I/O station(s) only
A station that exchanges I/O signals (bit data) by cyclic transmission. This station cannot perform
transient transmission.
Bit data input from a device station to the master station (For some areas in a local station, data are
input in the opposite direction.)
A generic term for AJ65BTB1-16D, AJ65SBTB1-16D, AJ65BT-64AD, AJ65BT-64DAV, AJ65BT-64DAI,
and GT15-J61BT13
A mode used to increase the number of link points by adding a Ver.2-compatible device station to an
existing system consisting of Ver.1-compatible device stations only. Different from the remote net Ver.2
mode, programs in the remote net Ver.1 mode can be used without change because RX/RY/RWr/RWw
data of a Ver.1-compatible device station are stored in the Ver.1-compatible buffer memory areas.
A mode used to communicate data with all stations (remote I/O station, remote device station, local
station, intelligent device station, and standby master station) in a CC-Link system.
There are three modes: remote net Ver.1 mode, remote net Ver.2 mode, and remote net additional
mode.
A mode used to configure a CC-Link system consisting of a master station and Ver.1-compatible device
station(s) only
A mode used to configure a CC-Link system containing a Ver.2-compatible device station.
Compared to the remote net Ver.1 mode, the number of link points per station is increased from 128 to
896 for RX/RY, and from 16 to 128 for RWr/RWw.
Bit data output from the master station to a device station (For some areas in a local station, data are
output in the opposite direction.)
Word data input from a device station to the master station (For some areas in a local station, data are
input in the opposite direction.)
Word data output from the master station to a device station (For some areas in a local station, data are
output in the opposite direction.)
A generic term for a remote I/O station and a remote device station
A process of restarting data link when a station recovers from an error
A MELSEC-QnA/A series module that has functions other than input and output, such as an A/D
converter module and D/A converter module
A station that serves as a master station to continue communications if the master station fails
A function of communication with another station, which is used when requested by a dedicated
instruction or a programming tool
A device station that supports the remote net Ver.1 mode
A device station that supports the remote net Ver.2 mode
Description