(b) When this function is used, the transmission delay time increases (compared with
when this function is not used).
When designing a new system by using an existing system as it is, confirm the delay time of the data from the
remote station before starting the system.
For the formula for calculating the transmission delay time when the block guarantee of cyclic data per station is used and
when it is not used, refer to
(c) When this function is used, the link refresh time increases (compared with when this
function is not used).
When designing a new system by using an existing system as it is, confirm the link refresh time before starting
the system.
For the formula for calculating the link refresh time when the block guarantee of cyclic data per station is used and when it is
not used, refer to
Page 454, Appendix 4.11.
Page 435, Appendix 4.2 to Page 443, Appendix 4.6.
CHAPTER 8 FUNCTIONS
163