Mitsubishi Electric L26CPU-BT User Manual page 416

Melsec-l cc-link system master/local module
Hide thumbs Also See for L26CPU-BT:
Table of Contents

Advertisement

Number
Name
SB0076
Temporary error invalid
(5E7
, b6)
station setting information
H
SB0077
Parameter receive status
(5E7
, b7)
H
SB0078
Host station switch change
(5E7
, b8)
detection
H
SB0079
Master station return
(5E7
, b9)
specification information
H
SB007A
Host standby master
(5E7
, b10)
station operation history
H
SB007B
Host master/standby
(5E7
, b11)
master operation status
H
Device station
refresh/compulsory clear
SB007C
setting status in case of
(5E7
, b12)
H
programmable controller
CPU STOP
SB007D
Connected devices auto-
(5E7
, b13)
detection function status
H
SB0080
Other station data link
(5E8
, b0)
*2
status
H
SB0081
Other station watchdog
(5E8
, b1)
timer error status
H
SB0082
Other station fuse blown
(5E8
, b2)
status
H
414
Description
Indicates whether there is a temporary error invalid station setting.
OFF: No setting
ON: Setting exists (information is stored in SW007C to SW007F)
Depending on the link refresh timing, SB0076 may be updated with
the time difference of one sequence scan from the update of the
temporary error invalid status (SW007C to SW007F).
Indicates the parameter receive status from the master station.
OFF: Reception complete
ON: Reception not complete
Detects changes to the host setting switch during data linking.
OFF: No changes detected
ON: Changes detected
Indicates whether the "Type" setting of the network parameters is
set to "Master station" or "Master station (Duplex function)."
OFF: Master station
ON: Master station (Duplex function)
Indicates whether the host station has operated as a standby
master station or not.
OFF: Not operated as a standby master station
ON: Operated as a standby master station
Indicates whether the host operates as the master or standby
master station.
OFF: Operates as the master station (controlling data link)
ON: Operates as the standby master station (standby)
Indicates the parameter-set device station refresh/compulsory
clear setting status in case of programmable controller CPU STOP.
OFF: Refresh
ON: Clears compulsorily
Stores the setting status of the connected devices auto-detection
function.
OFF: Do not read the model name of the device stations
ON: Read the model name of the device stations
Indicates the communication status with the device stations.
OFF: All stations normal
ON: Faulty station exists (information is stored in SW0080 to
SW0083)
Depending on the link refresh timing, SB0080 may be updated with
the time difference of one sequence scan from the update of the
other station data link status (SW0080 to SW0083).
Indicates the occurrence of a watchdog timer error in other
stations.
OFF: No error
ON: Error occurrence.
Depending on the link refresh timing, SB0081 may be updated with
the time difference of one sequence scan from the update of the
other station watchdog timer error occurrence status (SW0084 to
SW0087).
Indicates the fuse blown occurrence status at other stations.
(SW0088 to SW008B)
OFF: No error
ON: Error occurrence.
Depending on the link refresh timing, SB0082 may be updated with
the time difference of one sequence scan from the update of the
other station fuse blown status (SW0088 to SW008B).