Mitsubishi Electric L26CPU-BT User Manual page 35

Melsec-l cc-link system master/local module
Hide thumbs Also See for L26CPU-BT:
Table of Contents

Advertisement

(3) List of the "handy functions"
Item
Remote device station initialization
procedure registration function
Event issuance for the interrupt program
Automatic CC-Link startup
Reserved station function
Error invalid station setting function
Temporary error invalid station setting
function
Scan synchronous function
Data link stop/restart
Remote I/O station points setting
Master station duplication error cancel
function
Transmission speed auto-tracking setting
Status logging
Automatic detection of connected
devices
Data backup/restoration
Description
Programs for the initial setting become unnecessary, since the initial
settings in the remote device station are set at the network parameter. The
initial settings in the remote device station can be configured easily.
Since the interrupt program of the programmable controller CPU is
executed according to the established event issuance conditions, high
speed data receive processing can be made without being influenced by the
sequence scan.
The CC-Link starts automatically, only by turning the power on, and the
operation at the system construction can be checked.
By setting device stations that will be connected in the future as reserved
stations, they will not be treated as data link faulty stations.
Prevents device stations that may be powered off in the system
configuration from being treated as data link faulty stations by setting the
network parameters.
Changes device stations without detecting errors during online operation.
Also, prevents device stations, which are turned off in the system
configuration, from being treated as data link faulty stations temporarily.
Selects whether to synchronize or not the link scan with sequence scan.
In the synchronous mode, the link scan is performed synchronously with the
sequence scan. Therefore, the output data can be sent in high speed.
In the asynchronous mode, the link scan is performed not synchronized to
the sequence scan. Therefore, a high speed link scan can be performed
independent of the sequence scan.
Stops or restarts the data link that is being executed.
By stopping the data link, the program debug can be performed efficiently,
since data from other stations are not received, and data are not sent from
the host station.
Allows the I/O points of the remote I/O stations to be selected from among 8
points, 16 points and 32 points, reducing the number of reserved points.
The refresh device points of the programmable controller CPU and the link
refresh time can be saved.
Master station duplication errors can be canceled without turning the power
supply off to on, or without resetting the programmable controller CPU.
When the host station is a local station or a standby master station, an auto-
tracking occurs according to the transmission speed of the master station,
what eliminates setting errors of the transmission speed.
Logs the data link status of all stations.
When multiple stations repeat normal/faulty, or when determined stations
and later repeat normal/faulty, this function enables easy identification of the
causes, such as contact failure of the cable, or the noise occurrence
location.
The time of setting parameters can be reduced by automatically reading
information of device stations.
The model names of device stations can be read.
The setting data of the device station is backed up into the SD memory card
of the CPU module on the master station.
The setting data backed up into the SD memory card of the CPU module on
the master station is restored into the device module.
CHAPTER 3 SPECIFICATIONS
Reference
Page 165,
Section 8.3.1
Page 172,
Section 8.3.2
Page 176,
Section 8.3.3
Page 178,
Section 8.3.4
Page 179,
Section 8.3.5
Page 180,
Section 8.3.6
Page 182,
Section 8.3.7
Page 186,
Section 8.3.8
Page 188,
Section 8.3.9
Page 190,
Section 8.3.10
Page 108,
Section 7.5 (2)
Page 380,
Section 15.4.3
Page 83,
Section 7.3.2 (2)
iQ Sensor
Solution
Reference
Manual
iQ Sensor
Solution
Reference
Manual
33
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

L26cpu-pbtLj61bt11

Table of Contents