Mitsubishi Electric L26CPU-BT User Manual page 102

Melsec-l cc-link system master/local module
Hide thumbs Also See for L26CPU-BT:
Table of Contents

Advertisement

Item
Master Station
The setting is not required when the L series master/local module
Data Link Type
is used as a local station or standby master station.
Set the mode for the L series master/local module. (Refer to
Mode
Set the same mode as that of the master station to use an L series
master/local module as a standby master station.
Transmission
Set the transmission speed of the module.
Speed
The setting is not required when the L series master/local module
Total Module
is used as a local station or standby master station. (This does not
Connected
apply when "Master Station (Duplex Function)" is selected in
"Type".)
100
Description
Page 35, Section 3.4.)
Setting range

• Remote Net(Ver.1 Mode)
• Remote Net(Ver.2 Mode)
• Remote Net(Additional Mode)
• Offline
• Loop Test (for "Master Station (Duplex
Function)" only)
• H/W Test
(Default: Remote Net(Ver.1 Mode))
• Auto-tracking (selectable only for a local
station and standby master station)
• 156kbps
• 625kbps
• 2.5Mbps
• 5Mbps
• 10Mbps
(Default: For "Master Station (Duplex Function)":
156kbps, For local stations and standby station:
Auto-tracking)
