G(P).Rircv - Mitsubishi Electric L26CPU-BT User Manual

Melsec-l cc-link system master/local module
Hide thumbs Also See for L26CPU-BT:
Table of Contents

Advertisement

9.1.4

G(P).RIRCV

The G(P).RIRCV instruction automatically performs handshaking with an intelligent device station and reads data from
the buffer memory of the specified intelligent device station.
Available for modules that have signals for the handshake (e.g. AJ65BT-R2N).
Set
Internal device
data
(System, user)
Bit
Word
(S1)
(D1)
(S2)
(D2)
[Execution
[Instruction
condition]
symbol]
G.RIRCV
GP.RIRCV
Set data
*1
Device
Start I/O number of the module
Un
(First 2 digits of I/O No. with three digits)
(S1)
Start number of the device in which control data is stored.
(D1)
Start number of the device to which read data is to be stored.
(S2)
Start number of the device in which the interlock signals are stored.
Device that is turned ON for one scan upon completion of reading.
(D2)
(D2)+1 also turns ON at an abnormal completion.
*1
The file register of each of the local device and the program cannot be used as a device for setting data.
Link direct
device
File
J\
register
Bit
Word
Command
G.RIRCV
Command
GP.RIRCV
Description
CHAPTER 9 DEDICATED INSTRUCTIONS AND PROGRAMMING
Usable devices
Intelligent
function module
Index register
device
Z
U\G
Un
(S1)
Un
(S1)
Setting range
Within the range of the
specified device
Within the range of the
specified device
Within the range of the
specified device
Within the range of the
specified device
Constant
K, H
$
(D1)
(S2)
(D2)
(D1)
(S2)
(D2)
Data type
0 to FE
Binary 16 bits
H
Device name
Bit
9
Other
205

Advertisement

Table of Contents
loading

This manual is also suitable for:

L26cpu-pbtLj61bt11

Table of Contents