(3) Mode combination
(a) Whether system can be configured or not
The following tables indicate whether cyclic transmission can be made or not in each station.
Master station
Ver.2 mode
L series
master/local
Additional mode
module
Ver.1 mode
Master station
Ver.2 mode
L series
master/local
Additional mode
module
Ver.1 mode
*1
Although a local station in the remote net Ver.1 mode cannot perform data link with a Ver.2-compatible device station,
the status of the Ver.2-compatible device station is stored in Other station data link status (SW0080 to SW0083) for the
local station as well as that for the master station. (When the master station is normally performing data link with the
Ver.2-compatible device station, Other station data link status (SW0080 to SW0083) for the local station indicates "0:
Normal".) Note that cyclic data in the Ver.2-compatible device station will become "0" in the local station in the remote net
Ver.1 mode.
Transient transmission cannot be performed due to an error such as a timeout error.
Master station
Ver. 2 mode
Ver. 2 compatible
remote output RY
Station number 1
Station number 2
Station number 3
Station number 4
to
L series master/local module, QJ61BT11N, Q81BD-J61BT11, Q80BD-J61BT11N
Local station
Additional
Ver.2 mode
Ver.1 mode
mode
*2
Intelligent device station
Ver.2 compatible
Ver.1 compatible
: Cyclic transmission enabled, : Cyclic transmission enabled on condition, : Cyclic transmission disabled
Local station
Local station
Ver. 2 mode
Ver. 1 mode
(Station number 1:
(Station number 2:
Occupies 1 station)
Occupies 1 station)
Remote input RX
Station number 1
Station number 2
Station number 3
Station number 4
Ver. 2 compatible
remote input RX
Station number 1
Station number 2
Station number 3
Station number 4
to
double
Device station
Standby master station
Additional
Ver. 2 mode
mode
*1
*1
Device station
Remote device station
Ver.2 compatible
Remote device station
Ver. 2 compatible
(Station number 3:
Occupies 1 station)
All 0s
Remote output RY
quadruple
CHAPTER 3 SPECIFICATIONS
*3
A1SJ61BT11
A1SJ61QBT11
Standby
Local
master
station
station
Ver.1 mode
Ver.1 mode
Ver.1 mode
*1
*1
*4
Remote station
Remote I/O station
Ver.1 compatible
Ver.1 compatible
Remote device station
Ver. 1 compatible
(Station number 4:
Occupies 1 station)
Remote output RY
,
3
*3
39