3 Commissioning

3.3 Commissioning an axis

3.3
Commissioning an axis
Parameters for
general settings
(refer to
Chapter 5.6.2)
Parameters for
monitoring
(refer to
Chapter 5.6.2)
3-88
The appropriate parameters must be appropriately set to adapt the axis.
The most important parameters for general settings are:
S
P1
Axis type
S
P2
Travel per gearbox revolution
S
P3
Gearbox ratio
S
P4
Dimension unit
S
P8
Maximum speed
S
P10
Maximum velocity
S
P22
Maximum acceleration
The most important parameters for monitoring functions are:
S
P6
Software limit switch, start
S
P7
Software limit switch, end
S
P12
Maximum following error
S
P14
Standstill range
Note
There are neither software switches nor traversing range limits in the
n–set mode (from SW 2.0).
The drive must always be able to rotate endlessly and therefore to be
parameterized as rotary axis. It must be de–referenced.