02.99
04.01
24 V
Open/close the holding brake
Terminal 1
Terminal 2
Brake
procedural
control
Motor with integrated
holding brake (optional)
Parameter
P31
Function, terminal 1
P32
Function, terminal 2
P56.4
Open holding brake
P56.5
Monitoring, holding brake undervoltage
P56.6
Open the holding brake, also for an external holding brake
P58
Holding brake, brake opening time
P59
Speed, close holding brake
P60
Holding brake, brake delay time
P61
Holding brake, controller inhibit time
Inputs/outputs
P31 = 26
Terminal 1 as input with "open holding brake" function
P32 = 95
Terminal 2 as output with the "control external holding brake" function
Fig. 5-20 Example: Integrated holding brake – external holding brake
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
Ä Ä Ä
5 Description of the Functions
5.5 SIMODRIVE POSMO A functions
0 V
Ä Ä Ä
Í Í Í Í Í Í Í Í Í Í
External holding
brake
5
5-193