08.06
04.01
02.99
702 / P947.2
Electronics temperature
Cause
The electronics temperature is > 90 degrees Celsius and has been pre-
sent for longer than specified in P29 (electronics temperature tolerance
time).
An excessive electronics temperature is first signaled using warning
800 (warning, electronics temperature).
The ambient temperature is too high.
Remedy
Observe the de-rating characteristic.
Reduce ambient temperature.
Acknowledgement
Remove cause, set STW.7 = 1/0 and STW.0 = 0/1
Stop response
Braking with maximum acceleration (P22)
703 / P947.3
Overcurrent fault
Cause
The current limit has been exceeded.
The motor or the electronics is defective.
Remedy
Replace the positioning motor.
Acknowledgement
Remove cause, set STW.7 = 1/0 and STW.0 = 0/1
Stop response
Pulse suppression
704 / P947.4
Encoder fault
Cause
The signal sequence for the rotor position identification is not permissi-
ble.
The number of increments between two rotor position signals lies out-
side the permissible tolerance.
The motor or the electronics is defective.
Remedy
Replace the positioning motor.
Acknowledgement
Remove cause, set STW.7 = 1/0 and STW.0 = 0/1
Stop response
Pulse suppression
705 / P947.5
Standstill monitoring
Cause
The motor was moved out of the standstill area (P14) in the closed-loop
controlled status.
Note:
The fault can be changed-over to a warning using P30 (fault suppression).
Remedy
Check P14 (standstill area).
Acknowledgement
Remove cause, set STW.7 = 1/0 and STW.0 = 0/1
Stop response
Pulse suppression