Siemens SIMODRIVE POSMO A User Manual page 72

Distributed positioning motor on profibus dp
Hide thumbs Also See for SIMODRIVE POSMO A:
Table of Contents

Advertisement

06.05
04.01
02.99
Table 2-7
Technical data for the POSMO A – 300 W positioning motor, continued
Designation
Gearbox lifetime
Gearbox
data
Planetary
gearbox
S
Motor without gearbox:
S
Motor with 1–stage gearbox:
Weights
S
Motor with 2–stage gearbox:
S
Motor with 3–stage gearbox:
Climatic envi-
Relevant Standards
ronmental
conditions
Operating temperature
range
Climatic
Climatic
Extended operating
operating
temperature range
conditions
conditions
Relevant Standards
Transport and storage
temperature range
Climatic
Climatic
Relevant Standards
transport and
storage
storage
conditions
Mechanical
Relevant Standards
ambient
conditions
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
2 Installing and Connecting–Up
Description
A generally valid statement cannot be made about the lifetime
as a result of the various possible applications and the result-
ing load types as well as varying ambient conditions.
Factors which influence the lifetime include:
S
Duty types from continuous operation with one direction of
rotation up to extreme start/stop operation with load levels
from partial load up to full load and significant surge load-
ing.
S
Forced rotation accelerations or delays from the outside.
S
External mechanical loads in the form of a vibration and
shock.
S
The ambient temperature and humidity/moisture
3.9 kg
5.1 kg
5.4 kg
8.2 kg
IEC 68–2–1, IEC 68–2–2
–20 ... 45 _C
to +65 _C with continuous reduced motor current
according to DIN EN 60721 Part 3–3, Class 3K5
–40 ... +70 _C
according to DIN EN 60721, Part 3–1 and 3–2, Class 2K4 and
1K4
Note:
Data applies for components which have been packed ready
for transport.
IEC 68–2–32
2.6 Technical data
2-71
2

Advertisement

Table of Contents
loading

Table of Contents