Advertisement

5 Description of the Functions
5.6 Parameters for SIMODRIVE POSMO A
P0010 / 0A
Maximum motor velocity
300W 075W
Min
Standard
0
30000
Max. permissible velocity, dependent on the system.
The max. speed in P8 was not exceeded in operation.
Note:
This parameter has a gearbox-dependent factory default.
P0011 / 0B
Target range
300W 075W
Min
Standard
0
2
The parameter specifies the precise stopping range (precise stopping window).
Note:
P0011 may not be set too low, as otherwise a traversing task cannot be completed. The setting
is dependent on the encoder resolution and the gear ratio.
For SW 3.1 or higher, the following applies:
If the traversing range adaptation is active (compare P0704), the destination area will be deacti-
vated with the setting P0011 = 0.
In the case of a deactivated destination area, a traversing block will be terminated independent
of the positioning accuracy if the target position has been overrun
P0012 / 0C
Max. following error
300W 075W
Min
Standard
0
200000
The parameter specifies the maximum permissible following error.
Note:
The following error status is displayed using status signal ZSW.8 (no following error/following
error).
P0013 / 0D
Monitoring time
300W 075W
Min
Standard
0
100
After the motion block has been completed (position ref. value = target ref. value), this time is
started.
After the time has expired, the standstill monitoring and P gain are activated for standstill (P54,
P57).
P0014 / 0E
Standstill range
300W 075W
Min
Standard
0
200000
Tolerance range for the closed-loop position control at standstill.
Note:
The parameter value can be changed while traversing.
5-206
Max
Unit
2000000
MSR/min
Max
Unit
200000
MSR
Max
Unit
200000
MSR
Max
Unit
2000000
ms
Max
Unit
200000
MSR
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
Data type
Effective
I4
immed.
Data type
Effective
C4
immed.
Data type
Effective
C4
immed.
Data type
Effective
T4
immed.
Data type
Effective
C4
immed.
E Siemens AG 2013 All Rights Reserved
04.01
08.06
02.99