04.01
02.99
06.05
5.6.2
List of parameters
Reader's note
The parameters, listed in the following, are valid for all software
releases of SIMODRIVE POSMO A.
The complete list is updated corresponding to the Edition of the
documentation (refer to the Edition status in the header line) and
corresponds to the software release of SIMODRIVE POSMO A
documented here.
The parameters that are dependent on the software release are
appropriately identified.
Explanation of the
The parameters are listed as follows:
parameter list
Parameter number (examples)
P0010
Parameter 10 without index
P0082:28
Parameter 82 with index 0, 1, ... 27 (28 indices)
P0082:13
Parameter 82 with index 13
P0082:x
Parameter 82 with undefined index x
P0056.2
Parameter 56 bit 2
decimal hexadecimal
Pdddd || hh
075W 300W
Min
xx
Parameter description
Motor type
Specifies for which motor the parameter is valid.
075W
––> 75 W motor
300W
––> 300 W motor
Units
MSR: Dimension system grid
1 MSR = 1 mm
for P4 = 0
1 MSR = 1 degr. for P4 = 1
1 MSR = 1 inch for P4 = 2
Fig. 5-22 Parameter list
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
5.6 Parameters for SIMODRIVE POSMO A
Parameter text
word_word word_word
Standard
Max
Units
xx
xx
xx
Effective
S
immediately
when a change is made
When a parameter is changed, it is not permissible
that a traversing block is active. If a parameter can
be changed while the axis is traversing, then an
explicit reference is made.
In the "speed setpoint" mode, this means that STW.4
must be 0.
S
RO
––> Read Only
The parameter can only be read and not written into.
5 Description of the Functions
Data type
––> Refer to Chapter 4.3.1
Data type
Effective
yy
zz
––> becomes immediately effective
5
5-201