6 Fault Handling and Diagnostics

6.3 Analog test outputs

6.3
Analog test outputs
Description
!
Fig. 6-1
SIMODRIVE POSMO A test sockets with the cover removed
6-250
Analog test outputs are provided at the rear of the SIMODRIVE POSMO A
which are only accessible after the cover has been unscrewed.
Caution
Measurements may only be made in exceptional cases by
appropriately trained personnel. The "correct" text sockets must be
used, as short–circuits will permanently damage the module (refer to
Fig. 6-1).
The following parameters are available for the analog test sockets:
S
P33, P34, P35 address, shift factor and offset for DAU 1
S
P36, P37, P38 address, shift factor and offset for DAU 2
Which signal is output via the test outputs?
S
This is defined by entering an appropriate address in P33 or P36.
Screw type:
Torx T15/80
max. 3.9 Nm
Test pins
Pin
3
2
Pin
1
2
X11
2.54 2.54
Test sockets:
0.64 mm
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
SIMODRIVE POSMO A
with cover attached
Counter–sunk screw
M4 x 12 – 8.8
SN 63261
Pin
1
2
3
1
––> 75 W motor
3
––> 300 W motor
0.64
SIMODRIVE POSMO A
with cover removed
5 V
8 0 V of the
2.5 V
test signal
0 V
E Siemens AG 2013 All Rights Reserved
04.01
04.01
02.99
Function
DAU 1
DAU 2
M (reference)

Advertisement