Siemens SIMODRIVE POSMO A User Manual page 112

Distributed positioning motor on profibus dp
Hide thumbs Also See for SIMODRIVE POSMO A:
Table of Contents

Advertisement

08.02
02.99
Table 4-9
Description of the individual signals in the status word (ZSW) in the pos mode, continued
Bit
Signal name
No OFF 3 present/
No OFF 3 present/
5
5
OFF 3 present
OFF 3 present
Power–on inhibit/
6
No power–on inhibit
No power–on inhibit
Warning present/
Warning not present
7
(refer to Chapter 6.2)
No following error/following
8
error
Control requested/
local control
9
(from SW 1.4)
Reference position reached/
10
Outside the ref. position
Reference point set/
Reference point set/
11
11
no reference point set
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
4 Communications via PROFIBUS–DP
Signal status, signal description
1
No OFF 3 present
0
OFF 3 command present
1
Power–on inhibit
The system can only be powered–up using "OFF 1" fol-
lowed by "ON".
0
No power–on inhibit
1
Warning present
The drive still remains operational. Acknowledgment is
not required.
Which warning is present?
––> refer to P953 (warnings)
and
––> P954 (supplementary information, faults/warnings)
0
Warning not present
1
No following error
The dynamic target (reference) actual position compari-
son is made within the defined following error window.
The following error window is defined using P12 (maxi-
mum following error) (refer to Chapter 5.6.2).
0
Following error
1
Master, Class 1
0
No master Class 1 (but master, Class 2)
Note:
Before SW 1.4 the following applies:
The signal is not supported (a permanent "1" signal).
1
Reference position reached
Before SW 1.6 the following applies:
S
The position reference value is located at the end of a
traversing task within the positioning window.
S
The traversing task was interrupted by a fault, stop or
OFF commands.
From SW 1.6, the following applies:
The behavior is dependent on P56, bit 3:
S
P56.3=1
– The position reference value is located at the end
of a traversing task within the positioning window.
S
P56.3=0
– The position reference value is located at the end
of a traversing task within the positioning window.
– The traversing task was interrupted by a fault, stop
or OFF commands.
0
Outside the ref. position
1
Referencing was executed and is valid
0
Valid reference not available
4.2 Process data (PZD area)
4-111
4