Parameters which are not marked have the same function in both operating modes.
0
No function
1 I (STW.4)
Positioning operating mode: Operating condition positioning. Stop and reject
the actual traversing task on cancelation. Stop
Speed setpoint operating mode: Ramp-function generator enable. Stop with
maximum acceleration on cancelation.
2 I (STW.5)
Positioning operating mode: Operating condition positioning. Stop without
rejecting the actual traversing task on cancelation. Stop
Speed setpoint operating mode: Ramp-function generator START/Ramp-
function generator STOP. The actual speed remains constant on cancelation.
3 I (STW.6)
Positioning operating mode: Activate traversing task
Speed setpoint operating mode: Setpoint enable. Deceleration at the ramp on
cancelation.
4 I (STW.8)
Positioning operating mode: Jogging –
Speed setpoint operating mode: No function
5 I (STW.9)
Positioning operating mode: Jogging +
Speed setpoint operating mode: No function
6 I (STW.11)
Positioning operating mode: Referencing
Speed setpoint operating mode: No function
7 I (STW.12)
Positioning operating mode: Automatic single block.
Speed setpoint operating mode: No function
8 I (STW.13)
Positioning operating mode: External block change.
Speed setpoint operating mode: No function
9 I (STW.14)
Positioning operating mode: Read-in enable.
Speed setpoint operating mode: No function
10 I (RMB.0)
Positioning operating mode: Accept value directly in checkback byte (bit 0).
Speed setpoint operating mode: No function
11 I (RMB.1)
Positioning operating mode: Accept value directly in checkback byte (bit 1).
Speed setpoint operating mode: No function
12 I (RMB.2)
Positioning operating mode: Accept value directly in checkback byte (bit 2).
Speed setpoint operating mode: No function
13 I (RMB.3)
Positioning operating mode: Accept value directly in checkback byte (bit 3).
Speed setpoint operating mode: No function
14 I (RMB.4)
Positioning operating mode: Accept value directly in checkback byte (bit 4).
Speed setpoint operating mode: No function
15 I (RMB.5)
Positioning operating mode: Accept value directly in checkback byte (bit 5).
Speed setpoint operating mode: No function
16 I (RMB.6)
Positioning operating mode: Accept value directly in checkback byte (bit 6).
Speed setpoint operating mode: No function
17 I (RMB.7)
Positioning operating mode: Accept value directly in checkback byte (bit 7).
Speed setpoint operating mode: No function
18 I (STB.0)
Positioning operating mode: Accept value directly in start byte (bit 0).
Speed setpoint operating mode: No function
19 I (STB.1)
Positioning operating mode: Accept value directly in start byte (bit 1).
Speed setpoint operating mode: No function
20 I (STB.2)
Positioning operating mode: Accept value directly in start byte (bit 2).
Speed setpoint operating mode: No function
21 I (STB.3)
Positioning operating mode: Accept value directly in start byte (bit 3).
Speed setpoint operating mode: No function
22 I (STB.4)
Positioning operating mode: Accept value directly in start byte (bit 4).
Speed setpoint operating mode: No function
23 I (STB.5)
Positioning operating mode: Accept value directly in start byte (bit 5).
Speed setpoint operating mode: No function
24 I (STB.6)
Positioning operating mode: Accept value directly in start byte (bit 6).
Speed setpoint operating mode: No function