Fault Handling and Diagnostics

6.1

LED fault display

LED
An LED with the following significance is provided on the rear of the
fault display
positioning motor for diagnostics LED:
Table 6-1
What does an LED mean when it is bright?
LED display
Color
How is it lit?
None
off
Steady light
Red
Red
Flashing
Red/yellow
Alternating
flashing light
Steady light
Flashing
Green
Steady light
Yellow
Yellow
Flashing
Yellow/
Alternating
green
flashing light
(from
SW 1.2)
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
Is the
What status does the drive have?
bus
bus
What are the fault possibilities?
What are the fault possibilities?
OK?
S
no
The equipment is powered down or is defective
S
The power supply is incorrectly connected (incorrect
polarity)
S
no
Critical hardware defect, CPU cannot be used
S
Briefly after power up, even if the unit is OK
Disappears after the system has completely run up.
S
yes
Fault present, drive not ready
S
Read–out the fault number ––> refer to Chapter 6.2
S
no
Bus communications interrupted
S
yes
Standard operation
S
yes
Run–up, bus being initialized (baud rate adjustment,
configuration, parameterization)
S
No bus connection established:
– Bus cables not OK
– Address incorrectly set
– Bus parameterizing error
S
no
Bus run–up, incorrect configuration telegram
S
no
Bus run–up, incorrect parameterizing telegram
S
no
Standalone mode is active
––> Refer to Chapter 5.5.12
S
From SW 3.0:
P701 = 1 (telegram substitution activated) and the re-
ceived STW.10 = 0.
The drive is presently using the last valid STW (with
STW.10 = 1).