Siemens SIMODRIVE POSMO A User Manual page 260

Distributed positioning motor on profibus dp
Hide thumbs Also See for SIMODRIVE POSMO A:
Table of Contents

Advertisement

04.01
06.05
How do you
The drive unit is replaced as follows:
replace the drive
unit?
Caution
The positioning motor must be brought into a no–voltage condition
before the drive unit is replaced.
1. Remove the connection cover
2. Release the four screws retaining the drive unit
3. Remove the old drive unit
4. Mount the new drive unit
5. Tighten the four screws retaining the drive unit
6. Locate the connection cover and tighten the screws
7. Load the parameter set
8. Test the positioning motor
Note
For the separate version where the motor and drive unit are separated,
the installation sequence when replacing the drive unit is the same.
However, in this case, the drive unit is removed from the extension set
"separate version".
Order No. (MLFB)
The spare drive unit has the following Order No:
Order No. (MLFB):
Address to return
Refer to Chapter 7.1 under "Address to return the positioning motor" for
the drive unit
the address of the regional spare parts department that is responsible
(300 W motor)
for you.
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
7.3 Spare parts for SIMODRIVE POSMO A
– Tool
– Tool
– Tool
– Tighten the screws diagonally
– Tightening torque
– Tool
The parameter set provided must be downloaded into the new drive
unit from the old drive unit.
7 Installation and Service
Screwdriver, Size 4 (1.0 x 6.5)
Allen key SW 3
Allen key SW 3
2.5 – 3 Nm
Screwdriver, Size 4 (1.0 x 6.5)
6SN2157–0AA01–0BA1