Siemens SIMODRIVE POSMO A User Manual page 28

Distributed positioning motor on profibus dp
Hide thumbs Also See for SIMODRIVE POSMO A:
Table of Contents

Advertisement

06.05
04.01
Notice
24.When using SIMODRIVE POSMO A in UL–certified systems, a
25.If changes occur with respect to the normal operating condition,
26.Machines and systems equipped with SIMODRIVE POSMO A
Note
27.It is not permitted to open up the drive units! We recommend that a
28.The connection covers for POSMO A – 75 W and POSMO A – 300
29.At the end of the product lifetime, the individual parts and
30.Possible special versions (including connection systems) and types
31.Immediately contact the transport company if damage is identified
32.When connecting–up, it should be ensured that the connecting
33.Cables listed in the Siemens Catalog NC Z should be used when
34.Observe the rating plate data regarding type of construction and
35.The equipment must be mounted so that any thermal power loss is
E Siemens AG 2013 All Rights Reserved
SIMODRIVE POSMO A User Manual (POS1) – 08/2013 Edition
UL–certified varistor with the following properties is required in the
power supply cable.
for 24 V ––> V
= 38 V DC / I
N
e.g. SIOV–S20–K30 from EPCOS
for 48 V ––> V
= 65 V DC / I
N
e.g. SIOV–S20–K50 from EPCOS
This circuit is not required when using the DC–PMM (refer to
Chapter 2.2.3).
e.g. increased temperatures, noise or oscillation, if in doubt, power
down the motor. The cause should then be determined and if
necessary a SIEMENS Service Center should be contacted.
must be in full compliance with the protective requirements of the
EMC Directive.
The plant/machine manufacturer is responsible in ensuring this.
SIEMENS Service Center carries–out any repair or service work.
W cannot be interchanged. This means that the connection cover
for the 75 W motor does not fit on the 300 W motor and vice versa.
components should be disposed of according to the regulations of
the particular country.
of construction can differ regarding the technical details! If there is
any uncertainty, we urgently recommend that you contact the
manufacturer (specifying the type designation and serial number) or
have the equipment repaired by a SIEMENS Service Center.
after the equipment has been shipped. In case of damage, the drive
units should not be commissioned.
cables are protected against torsional stressing, strain and
pressure; it should also be ensured that cables cannot kink.
connecting–up SIMODRIVE POSMO A.
degree of protection to ensure that they coincide with the conditions
at the point of installation!
adequately dissipated.
1 Product Brief
1.3 Safety guidelines
= 2000 A
max
= 6500 A
max
1
J
1-27

Advertisement

Table of Contents
loading

Table of Contents